Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 942-982-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Water solubility
Administrative data
Link to relevant study record(s)
- Endpoint:
- transformation / dissolution of metals and inorganic metal compounds
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 27 May 2016 to 11 July 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Series on Testing and Assessment No. 29 (23-Jul-2001): Guidance document on transformation/dissolution of metals and metal compounds in aqueous media
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: EEC guideline SANCO/3029/99 rev. 4 dated 11/07/00: Working document “Guidance for generating and reporting methods of analysis in support of residue data requirements for Annex II (part A, Section 4) and Annex III (part A, Section 5)
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- other: Transformation / dissolution test
- Specific details on test material used for the study:
- TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: None
- Final preparation of a solid: 1 mg of test item was added to the test medium - Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 24 h
- Test conditions:
- test medium pH 6, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 7 d
- Test conditions:
- test medium pH 6, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 14 d
- Test conditions:
- test medium pH 6, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 28 d
- Test conditions:
- Test medium pH 6, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 24 h
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 7 d
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 14 d
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- titanium
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 28 d
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Ti).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 24 h
- Test conditions:
- Test medium pH 6, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 7 d
- Test conditions:
- Test medium pH 6, room temperature.
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 14 d
- Test conditions:
- Test medium pH 6, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 28 d
- Test conditions:
- Test medium pH 6, room temperature.
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 24 h
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 7 d
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 14 d
- Test conditions:
- Test medium pH 8, room temperature
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Type of test:
- full transformation/dissolution test - metals and sparingly soluble metal compounds
- Mean dissolved conc.:
- < 0.5 µg/L
- Element analysed:
- antimony
- Loading of aqueous phase:
- 1 mg/L
- Incubation duration:
- 28 d
- Test conditions:
- Test medium pH 8, room temperature.
- Remarks on result:
- other: lower than the Limit of Detection (L.O.D. = 0.50 ug/L for Sb).
- Details on results:
- After 28 days, no antimony or titanium were released above the limit of detection of 0.5 µg/L at pH 6 and pH 8 from uverithe at a loading of 1 mg/L. Considering an initial uverithe load of 1 mg/L and the maximum possible release of 233.50 μg Ti/L for titanium and 322.45 μg Sb/L for antimony, the test results indicate that the test item is essentially insoluble in both test media.
- Conclusions:
- After 28 days, no antimony or titanium were released above the limit of detection of 0.5 µg/L at pH 6 or pH 8 from uverithe. The test item is essentially insoluble in both test media.
- Executive summary:
The transformation/dissolution test with uverithe was conducted at a loading rate of 1 mg/L in two aqueous media at pH 6 and pH 8 (Martinez 2016). The study was performed according the OECD 29 guideline and is a GLP-compliant. This study is considered reliable without restrictions (Klimisch 1) and is suitable for use as a key study for this endpoint.
In the 28-day transformation/dissolution test with uverithe, no antimony or titanium were released above the limit of detection of 0.5 µg/L at pH 6 and pH 8 form uverithe. Considering an initial uverithe load of 1 mg/L and the maximum possible release of 233.50 μg Ti/L for titanium and 322.45 μg Sb/L for antimony, the test results indicate that the test item is essentially insoluble in both test media.
Reference
TABLE 1a Summary table: Uverithe 28-day full test with a loading of 1 mg/L at pH 6 for Titanium
Full test 28 days at 1 mg/L pH 6 2926587-001 |
47Ti (µg/L) |
Full test 28 days at 1 mg/L pH 6 2926587-001 |
47Ti (µg/L) |
||
Test medium pH 6 T0 hour |
Mean |
n.d. |
Test medium pH 6 T7 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T2 hours |
Mean |
n.d. |
Test medium pH 6 T14 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T6 hours |
Mean |
n.d. |
Test medium pH 6 T21 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T24 hours |
Mean |
n.d. |
Test medium pH 6 T28 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T4 days |
Mean |
n.d. |
- |
||
S.D. |
- |
||||
RSD% |
- |
n.d.: lower than the Limit of Detection (L.O.D. = 0.50 µg/L for Ti).
The between-vessel variation was less than 20% recommended by OECD Series No. 29.
TABLE 1b Summary table: Uverithe 28-day full test with a loading of 1 mg/L at pH 8 for Titanium
Full test 28 days at 1 mg/L pH 8 2926587-001 |
47Ti (µg/L) |
Full test 28 days at 1 mg/L pH 8 2926587-001 |
47Ti (µg/L) |
||
Test medium pH 8 T0 hour |
Mean |
n.d. |
Test medium pH 8 T7 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T2 hours |
Mean |
n.d. |
Test medium pH 8 T14 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T6 hours |
Mean |
n.d. |
Test medium pH 8 T21 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T24 hours |
Mean |
n.d. |
Test medium pH 8 T28 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T4 days |
Mean |
n.d. |
- |
||
S.D. |
- |
||||
RSD% |
- |
n.d.: lower than the Limit of Detection (L.O.D. = 0.50 µg/L for Ti).
The between-vessel variation was less than 20% recommended by OECD Series No. 29.
TABLE 1c Summary table: Uverithe 28-day full test with a loading of 1 mg/L at pH 6 for Antimony
Full test 28 days at 1 mg/L pH 6 2926587-001 |
123Sb (µg/L) |
Full test 28 days at 1 mg/L pH 6 2926587-001 |
123Sb (µg/L) |
||
Test medium pH 6 T0 hour |
Mean |
n.d. |
Test medium pH 6 T7 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T2 hours |
Mean |
n.d. |
Test medium pH 6 T14 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T6 hours |
Mean |
n.d. |
Test medium pH 6 T21 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T24 hours |
Mean |
n.d. |
Test medium pH 6 T28 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 6 T4 days |
Mean |
n.d. |
- |
||
S.D. |
- |
||||
RSD% |
- |
n.d.: lower than the Limit of Detection (L.O.D. = 0.50 µg/L for Sb).
The between-vessel variation was less than 20% recommended by OECD Series No. 29.
TABLE 1d Summary table: Uverithe 28-day full test with a loading of 1 mg/L at pH 8 for Antimony
Full test 28 days at 1 mg/L pH 8 2926587-001 |
123Sb (µg/L) |
Full test 28 days at 1 mg/L pH 8 2926587-001 |
123Sb (µg/L) |
||
Test medium pH 8 T0 hour |
Mean |
n.d. |
Test medium pH 8 T7 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T2 hours |
Mean |
n.d. |
Test medium pH 8 T14 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T6 hours |
Mean |
n.d. |
Test medium pH 8 T21 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T24 hours |
Mean |
n.d. |
Test medium pH 8 T28 days |
Mean |
n.d. |
S.D. |
- |
S.D. |
- |
||
RSD% |
- |
RSD% |
- |
||
Test medium pH 8 T4 days |
Mean |
n.d. |
- |
||
S.D. |
- |
||||
RSD% |
- |
n.d.: lower than the Limit of Detection (L.O.D. = 0.50 µg/L for Sb).
The between-vessel variation was less than 20% recommended by OECD Series No. 29.
Description of key information
Based on the results of the transformation/dissolution study, uverithe is considered essentially insoluble in the media tested. After 28 days, no antimony or titanium were released above the limit of detection of 0.5 µg/L after 28 days from the test item at pH 6 and pH 8.
Key value for chemical safety assessment
Additional information
The transformation/dissolution test with uverithe was conducted according to the OECD 29 guideline (Pardo Martinez 2016). TD tests are a standard method for assessing the solubility of poorly soluble metal substances and provide additional data that cannot be obtained from a standard OECD 105 water solubility study. This is a guideline, GLP-compliant study and is considered reliable without restrictions (Klimisch 1). It is suitable for use as a key study for this endpoint.
The 28 -day test was performed in two aqueous media at pH 6 and pH 8 at a loading rate of 1 mg/L. In the 28-day transformation/dissolution test with uverithe, no antimony or titanium were released above the limit of detection of 0.5 µg/L after 28 days from the test item at pH 6 or pH 8. Considering an initial uverithe load of 1 mg/L and the maximum possible release of 233.50 μg Ti/L for titanium and 322.45 μg Sb/L for antimony (calculated from the test item composition), the test results indicate that the test item is essentially insoluble in both test media.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.