Registration Dossier

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is a solid having a melting point <= 160°C
other:
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: based on USP-NF method <741>
GLP compliance:
no
Type of method:
capillary method
Key result
Melting / freezing pt.:
68 °C
Atm. press.:
1 013 hPa
Conclusions:
The melting point is 68C at 1013 hPa
Executive summary:

The melting point is 68C at 1013 hPa using test method based on USP-NF method <741>.

Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D 92
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Anton Paar Model CLA 5 Automatic Cleveland Flash & Fire Point Tester
Key result
Flash point:
259 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 259C > 200C at 1013 hPa
Executive summary:

Flash point is 259C > 200C at 1013 hPa using Cleveland Open Cup equivalent method to ASTM D92

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion