Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test substance did not ignite and propagate combustion along 200 mm of the powder train within the 4 minute test period; therefore, it is not considered highly flammable

Description of key information

The test substance did not ignite and propagate combustion along 200 mm of the powder train within the 4 minute test period; therefore, it is not considered highly flammable

Key value for chemical safety assessment

Additional information

Flammability was determined using method A.10 (Sinning DJ 2006)

Justification for classification or non-classification

Not flammable