Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
other: DIN 51758 Testing of liquid petroleum products and other combustible liquids; determination of flash point by pensky-martens closed tester
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks on result:
no flash point up to 100°C
Interpretation of results:
other: not classified, according to the CLP Regulation (EC) 1272/2008
Conclusions:
No flash point up to 100 °C
Executive summary:

The flash point was tested according to the DIN 51758 method, testing of liquid petroleum products and other combustible liquids; determination of flash point by pensky-martens closed tester. No flash point was recorded up to 100 °C.

Conclusion

No flash point up to 100 °C, thus the substance does not meet the criteria to be classified as flammable liquid, according to the CLP Regulation (EC) No 1272/2008.

Description of key information

No flash point up to 100 °C

Key value for chemical safety assessment

Additional information

DIN 51758 method