Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
DIN EN ISO 2719
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 100 °C
Atm. press.:
1 013 hPa

The DSC-onset-temperature of the sample is 125°C. Consequently, for safety reasons the test-temperature was restricted to 100°C. Up to 100°C no flashpoint could be detected.

Description of key information

Flash point > 100 °C at 1013 hPa

Key value for chemical safety assessment

Additional information

The DSC-onset-temperature of the sample is 125 °C. Consequently, for safety reasons the test-temperature was restricted to 100 °C. Up to 100 °C no flashpoint could be detected.