Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
DIN EN ISO 2719
Deviations:
no
GLP compliance:
no
Other quality assurance:
ISO/IEC 17025 (General requirements for the competence of testing and calibration laboratories)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
> 100 °C
Atm. press.:
1 013 hPa

The DSC-onset-temperature of the sample is 125°C. Consequently, for safety reasons the test-temperature was restricted to 100°C. Up to 100°C no flashpoint could be detected.

Description of key information

Flash point > 100 °C at 1013 hPa

Key value for chemical safety assessment

Additional information