Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
6/9/2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: The information is based on a reliable non-GLP in-house study using the closed cup method equivalent to EU A.9 (Flash-Point).
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Key result
Flash point:
81 °C
Atm. press.:
101 300 Pa
Conclusions:
The Flash Point of Oxaspirane-819 is 81°C in a reliable non-GLP study using the closed cup method equivalent to the EU Method A.9 (Flash-Point).
Executive summary:

The Flash Point of Oxaspirane-819 is 81°C using the closed cup method study equivalent to EU Method A.9 (Flash-Point).

Description of key information

The Flash Point of Oxaspirane-819 is 81°C using the closed cup method study equivalent to EU Method A.9 (Flash-Point).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
81 °C

Additional information