Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
weight of evidence
Study period:
16 Jan 2018
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The Limit of Quantification of the method used is higher than expected based on OECD Guideline 104.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
March 23, 2006
Deviations:
no
GLP compliance:
yes
Type of method:
static method

Test material

Constituent 1
Reference substance name:
Dodecanoic acid, monoester with oxybis[propanediol]
EC Number:
619-220-9
Cas Number:
96499-68-2
Molecular formula:
not applicable, the substance is UVCB
IUPAC Name:
Dodecanoic acid, monoester with oxybis[propanediol]

Results and discussion

Vapour pressureopen allclose all
Temp.:
25 °C
Vapour pressure:
< 133 Pa
Temp.:
50 °C
Vapour pressure:
< 133 Pa

Any other information on results incl. tables

Test temperature (°C)

Vapor pressure (Pa)

Measured value

Average

25

<133

<133

<133

<133

50

<133

<133

<133

<133

 

The value was regarded as <133 Pa because the vapour pressure was lower than the measurement limit.

 

No adverse effects on the reliability of this test were noted.

Applicant's summary and conclusion