Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 November 2000
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
>= 120 - <= 124 °C
Atm. press.:
101.325 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the test substance is 122 +/- 2°C at 99.71 kPa. It does meet the criteria for classification according to Regulation (EC) No.1272/2008.
Executive summary:

The flash point of the substance was determined during a GLP-compliant study performed in accordance with EU Method A.9.

The flash point was determined to 122 +/- 2°C at 101.325 kPa.

The test substance does meet the criteria for classification according to Regulation (EC) No.1272/2008.

Description of key information

The flash point of the substance was determined during a GLP-compliant study performed in accordance with EU Method A.9.

The flash point was determined to 122 +/- 2°C at 101.325 kPa.

The test substance does meet the criteria for classification according to Regulation (EC) No.1272/2008.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
122 °C