Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
16th August to 31st August 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
239.5 °C
Atm. press.:
1 013 hPa
Interpretation of results:
GHS criteria not met
Conclusions:
Imwitor 375 has a flash point of 239.5 °C
Executive summary:

The test item Imwitor 375 has a flash point of 239.5 °C, as determined according to EC Method A.9 using a closed cup Pensky-Martens apparatus.

Description of key information

Imwitor 375 has a flash point of 239.5°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
239.5 °C

Additional information

The test item Imwitor 375 has a flash point of 239.5°C, as determined according to EC Method A.9 using a closed cup Pensky-Martens apparatus.