Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 236-308-9 | CAS number: 13291-61-7
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Vapour pressure
Administrative data
Link to relevant study record(s)
- Endpoint:
- vapour pressure
- Type of information:
- (Q)SAR
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- accepted calculation method
- Justification for type of information:
- For the calculation EPI Suite (MPBPVP v1.43) was used.
This is an accepted calculation method and EPI Suite is generally recommended by the Guidance documents. - Qualifier:
- no guideline required
- Principles of method if other than guideline:
- For a calculation method a test guideline is generally not required.
- GLP compliance:
- no
- Remarks:
- GLP compliance is only relevant for experimental studies and thus not applicable.
- Key result
- Test no.:
- #1
- Temp.:
- 25 °C
- Vapour pressure:
- 0 Pa
- Key result
- Test no.:
- #1
- Temp.:
- 25 °C
- Vapour pressure:
- 0 mm Hg
- Conclusions:
- The vapour pressure calculated with EPI Suite was determined to be 1.03E-10 Pa at 25 °C.
- Executive summary:
EPI Suite and the implemented calculation method (MPBPVP v1.43) are accepted methods for the determination of physical-chemical properties by QSAR.
A very low vapour pressure for the test substance is reasonable as it is a solid substance that does not melt or sublime up to ca. 200 °C.
The registrant is aware of remeining uncertainties caused by the methods used for calculation.
Nevertheless an experimental study is not justified because of the very low vapour pressure. The relevant guideline (OECD 104) describes different methods with their recommended ranges. The lowest detectable limit is stated with 1E-10. Thus the vapour pressure of the test substance can be considered to be around or even below the limit that can be detected with recommended experimental methods.
Reference
Description of key information
The vapour pressure calculated with EPI Suite was determined to be 1.03E-10 Pa at 25 °C.
Key value for chemical safety assessment
- Vapour pressure:
- 0 Pa
- at the temperature of:
- 25 °C
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.