Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Nov 6, 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
99.5 °C
Atm. press.:
1 atm
Interpretation of results:
GHS criteria not met
Remarks:
According to EU EC Reg 1272/2008, as amended
Conclusions:
It was concluded from the study observation that the test item has a flash point of 99.5 °C (PMCC).
Executive summary:

It was concluded from the study observation that the test item has a flash point of 99.5 °C.

Description of key information

It was concluded from the study observation that the test item has a flash point of 99.5 °C (PMCC).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
99.5 °C

Additional information

The flash point was determined in a non-GLP study according to ASTM D93 (PM closed cup method). The measured flash point was reported to be 99.5 °C.