Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 211-941-3 | CAS number: 717-74-8
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- Dec 3, 2014 to Apr 28, 2015
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- 2001
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Version / remarks:
- 2008
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Designation in Test Facility 14111701G
- Expiration date of the lot/batch: 17.Nov.2016/Batch No. 6F11027000
- Purity: 96% - Radiolabelling:
- no
- Test temperature:
- 25 ± 0.5°C
- Details on study design: HPLC method:
- EQUIPMENT
- Apparatus: HPLC
- Eluent: isocratic methanol/water 55/45 (% v/v), degassed
- Flow rate: 0.8 mL/min
- Injection volume: 20 µL
- Column: Reprosil PurCN 125*4.6 mm, with pre-column Phenom-enex Security Guard CN, 4x3 mm
- Cyanopropyl chemical bound resin on a silica base column
- Wavelength for evaluation: 200nm
DETERMINATION OF DEAD TIME
- Method: measured using an unretained compound (sodium nitrate), included in the mix of the reference items
REFERENCE SUBSTANCES
- Identity: sodium nitrate; phenol; methylbenzoate; naphthalene; 1,2,3-trichlorobenzene; phenanthrene; DDT
- reference items dissolved in the mobile phase; all were analytical grade
DETERMINATION OF RETENTION TIMES
- Concentration injected of test substance introduced in the column: 5 mg/L
- Concentration injected of reference substances: sodium nitrate (2.0 mg/L); phenol (4.0 mg/L); methylbenzoate (2.0 µg/L); naphthalene (2.0 mg/L); 1,2,3-trichlorobenzene (4.0 mg/L); phenanthrene (3.0 mg/L); DDT (10.0 mg/L)
- Intervals of calibration: 6 measurements of the capacity factors of the reference items
REPETITIONS
- Number of determinations: 3
EVALUATION
- Calculation of capacity factors k': yes
- Calculation of retention times: Retention times were measured
- Determination of the log Koc value: Each log Koc from the 3 determinations were calculated using the calculated capacity factors - Analytical monitoring:
- yes
- Computational methods:
- Adsorption coefficient per organic carbon (Koc): The HPLC retention times of the seven peaks of the reference item mix and the rentation time of the peak of the test item were used for further calculations
- Key result
- Type:
- log Koc
- Value:
- ca. 4.426 dimensionless
- Details on results (HPLC method):
- - Mean retention times of reference substances used for calibration: sodium nitrate (1.113 min); phenol (2.705 min); methylbenzoate (3.093 min); naphthalene (4.305 min); 1,2,3-trichlorobenzene (4.941 min); phenanthrene (6.939 min); DDT (14.540 min)
- Details of fitted regression line (log k' vs. log Koc): r2 = 0.999
- Average retention data for test substance: 8.314 min - Validity criteria fulfilled:
- yes
- Remarks:
- Criteria Parameters:Range (Max - Min. log Koc); Value within Range of Calibration
- Conclusions:
- Based on the calibration function log K versus log Koc, the corresponding log Koc was determined as 4.426 ± 0.011 (mean± standard deviation). The study was performed using a HPLC with a cyanopropyl chemical bound resin on a silica base column.
- Executive summary:
Based on the calibration function log K versus log Koc, the corresponding log Koc was determined as 4.426 ± 0.011 (mean± standard deviation). The study was performed using a HPLC with a cyanopropyl chemical bound resin on a silica base column.
Reference
Description of key information
Following the OECD 121 HPLC method and based on the calibration function log K versus log Koc, the corresponding log Koc was determined as 4.426 ± 0.011 (mean± standard deviation).
Key value for chemical safety assessment
- Koc at 20 °C:
- 26 668
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.