General advice :
Move out of dangerous area.
Consult a physician.
Show this safety data sheet to the doctor in attendance.
Do not leave the victim unattended.

If inhaled :
If unconscious, place in recovery position and seek medical advice.
If symptoms persist, call a physician.

In case of skin contact :
Take off contaminated clothing and shoes immediately.
If on skin, rinse well with water.

In case of eye contact :
Remove contact lenses.
Immediately flush eyes for at least 15 minutes. Get medical attention.

If swallowed :
Induce vomiting immediately and call a physician.
Keep respiratory tract clear.
Do not give milk or alcoholic beverages.
Never give anything by mouth to an unconscious person.
Take victim immediately to hospital.

Fire-fighting measures

Extinguishing media
Suitable extinguishing media : Dry chemical, Alcohol-resistant foam, Carbon dioxide (CO2), Water spray

Unsuitable extinguishing media: no data available

Special hazards arising from the substance or mixture
Specific hazards during firefighting : Do not allow run-off from fire fighting to enter drains or water courses.

5.3 Advice for firefighters
Special protective equipment for firefighters : Wear self-contained breathing apparatus for firefighting if necessary.
Further information : Collect contaminated fire extinguishing water separately. This must not be discharged into drains.
Fire residues and contaminated fire extinguishing water must be disposed of in accordance with local regulations.

Accidental release measures

Personal precautions, protective equipment and emergency procedures
Personal precautions : no data available

Environmental precautions
Environmental precautions : Prevent product from entering drains.
If the product contaminates rivers and lakes or drains inform respective authorities.

Methods and materials for containment and cleaning up
Methods for cleaning up : Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust).
Keep in suitable, closed containers for disposal.

Handling and storage

Precautions for safe handling

Advice on safe handling :
Do not breathe vapours/dust.
Avoid exposure - obtain special instructions before use.
Avoid contact with skin and eyes.
Smoking, eating and drinking should be prohibited in the application area.
Dispose of rinse water in accordance with local and national regulations.

Advice on protection against fire and explosion : Normal measures for preventive fire protection.

Temperature class : no data available

Fire-fighting class : no data available

Dust explosion class : no data available

Conditions for safe storage, including any incompatibilities

Requirements for storage areas and containers :
Keep container tightly closed in a dry and well-ventilated place.
Containers which are opened must be carefully resealed and kept upright to prevent leakage.
Observe label precautions.
Electrical installations / working materials must comply with the technological safety standards.

Further information on storage conditions :
Ambient / 10-30°C (50-85°F)
Dry, well ventilated, preferably full, hermetically sealed

Advice on common storage : Protect against light.

German storage class : no data available
Other data : No decomposition if stored and applied as directed.

Transport information

Land transport (ADR/RID)

UN number:
UN2810
Shippingopen allclose all
Class:
II
Packaging group:
6.1
SpecialProvisionsopen allclose all

Inland waterway transport (ADN(R))

UN number:
UN 2810
Shippingopen allclose all
Class:
II
Packaging group:
6.1
Remarksopen allclose all

Marine transport (IMDG)

UN number:
UN 2810
Class:
II
Packaging group:
6.1
Remarksopen allclose all

Air transport ICAO/IATA

UN number:
UN 2810
Class:
II
Packaging group:
6.1
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Control parameters
Contains no substances with occupational exposure limit values.

Personal protective equipment
Respiratory protection : Use only in well-ventilated areas.
In case a risk analysis proved the cartridge respirator as acceptable, use type: ABEK-P3 (EN 14387) respirator cartridges as a backup to engineering controls.
In absence of engineering controls, use self-contained breathing apparatus or full face supplied air respirators.
Use respirators and components tested and approved under appropriate government standards such as CEN (EU).

Hand protection :
Use gloves when handling substance in open systems.
Inspect gloves prior to use. Train operators for proper use.
If only incidental exposure is expected: (work without direct contact to substance) use gloves tested according EN 16523-1 breakthrough times at least 10 minutes, tested for chemicals indicated in chapter 3 of this SDS. Change gloves frequently.
If direct skin contact is expected: use gloves tested according to EN 16523-1, tested for chemicals indicated in chapter 3 of this SDS. Permeation time must exceed contact time.

Eye protection : Use safety glasses and faceshield tested according to EN 166.

Skin and body protection :
Wear working clothes covering arms and legs.
The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace. Use apron or complete chemical suit if exposure is expected.

Hygiene measures :
Do not eat, drink or smoke during work.
Wash and dry hands after finished working.
Protective measures : Exposure assessment: Exposure is dependent on the product being handled, the potential for chemical release, and any resulting airborne concentrations or dermal contact. Since product handling and release scenarios vary, and no two workplaces are exactly alike, it is recommended that the potential for exposure be assessed prior to the product’s use or introduction. Exposure assessments should be performed
by an occupational hygienist, industrial hygienist, or other qualified occupational or environmental health professional.
An exposure assessment should be conducted to determine the efficacy of any ventilation and the need for additional respiratory protection.
PPE is always the last resort to avoid exposure. In any case technical and organisational measures have to be explored and used prior to the selection of PPE. The PPE selection is for operators trained to work with chemicals according to good industrial hygiene and safety practice. Operators have to be trained and used to PPE handling.

Environmental exposure controls
General advice : Prevent product from entering drains.
If the product contaminates rivers and lakes or drains inform respective authorities.

Stability and reactivity

Reactivity: none

Chemical stability: The product is chemically stable.

Possibility of hazardous reactions: Hazardous reactions : No decomposition if stored and applied as directed.

Conditions to avoid
Conditions to avoid : no data available

Incompatible materials
Materials to avoid : no data available

Hazardous decomposition products
Hazardous decomposition products : no data available
Thermal decomposition : no data available

Disposal considerations

Waste treatment methods
Product :
The product should not be allowed to enter drains, water courses or the soil.
Do not contaminate ponds, waterways or ditches with chemical or used container.
Send to a licensed waste management company.

Contaminated packaging :
Empty remaining contents.
Dispose of as unused product.
Do not re-use empty containers.