Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
oxidising solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
06 December-19 December, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.17 (Oxidising Properties (Solids))
Version / remarks:
31 May 2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Reference substance name:
1-naphthalenesulfonic acid, 5-[(4-hydroxyphenyl)amino]-8-(phenylamino)-, reaction products with sodium sulfide (Na2(Sx)), leuco derivatives
EC Number:
235-521-4
EC Name:
1-naphthalenesulfonic acid, 5-[(4-hydroxyphenyl)amino]-8-(phenylamino)-, reaction products with sodium sulfide (Na2(Sx)), leuco derivatives
Cas Number:
12262-32-7
Molecular formula:
not applicable
IUPAC Name:
Reaction product of 1-naphthalenesulfonic acid, 5-[(4-hydroxyphenyl)amino]-8-(phenylamino)- with sodium polysulfide, leuco derivatives
Test material form:
solid
Specific details on test material used for the study:
Expiry date 26 March 2020

Study design

Contact with:
powdered cellulose

Results and discussion

Test results (Oxidising solids)
Key result
Sample tested:
test mixture as specified
Remarks:
Oxidiser cellulose-mixtures containing 10 to 90 % weight of oxidiser in 10 % increments were prepared.
Parameter:
burning time of reaction over a distance of 200 mm
Remarks on result:
other: The maximum burning rate of the test item in different mixtures was found to be lower than the burning rate of the reference mixture in the Main Test.
Remarks:
C.I. Leuco Sulfur Green 2 is not considered as an oxidizing substance.

Any other information on results incl. tables

Reference measurement*

Ratio

Ba(NO3)2: Cellulose

Weight

Ba(NO3)2(g)

Weight

Cellulose (g)

Burning time (sec)

Burning rate (mm/sec)

10 : 90 %

2.00

18.00

527

0.38

20 : 80 %

4.00

16.00

457

0.44

30 : 70 %

6.00

14.00

401

0.50

40 : 60 %

6.00

9.00

463

0.43

50 : 50 %

10.00

10.00

469

0.43

60 : 40 %

9.00

6.00

519

0.39

70 : 30 %

21.00

9.00

751

0.27

80 : 20 %

40.00

10.00

-

-

90 : 10 %

45.00

5.00

-

-

* was measured in a separate study, under the study number: 805-155-1821

 

Main Test

Ratio

Test item : Cellulose

Weight

Test item (g)

Weight

Cellulose (g)

Burning time

(sec)

Burning rate (mm/sec)

Type of burning

10 : 90 %

2.00

18.00

-

-

ignited but did not propagate

20 : 80 %

4.00

16.00

-

-

ignited but did not propagate

30 : 70 %

6.00

14.00

-

-

ignited but did not propagate

40 : 60 %

12.00

18.00

-

-

no ignition

50 : 50 %

15.00

15.00

-

-

no ignition

60 : 40 %

18.00

12.00

-

-

no ignition

70 : 30 %

14.00

6.00

-

-

no ignition

80 : 20 %

16.00

4.00

-

-

no ignition

90 : 10 %

18.00

2.00

-

-

no ignition

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The cone-shaped pile formed during the Preliminary Test could not be ignited therefore the Main Test was performed.
The maximum burning rate of the test item in different mixtures was found to be lower than the burning rate of the reference mixture in the Main Test. C.I. Leuco Sulfur Green 2 is not considered as an oxidizing substance.
Executive summary:

The purpose of this study was to investigate the oxidizing properties of the test item.

The maximum burning rate of the test item in different mixtures was found to be lower than the burning rate of the reference mixture in the Main Test. C.I. Leuco Sulfur Green 2 is not considered as an oxidizing substance.