Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 201-818-2 | CAS number: 88-30-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- from 2002-07-15 to 2003-01-03
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- EPA OPPTS 830.7550 (Partition Coefficient, n-octanol / H2O, Shake Flask Method)
- Deviations:
- no
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Deviations:
- no
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient - Shake Flask Method)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- flask method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- 2.68
- Temp.:
- 23 °C
- pH:
- > 3.8 - < 5.5
- Conclusions:
- The log Pow of the test item was determined to be 2.68 at 23 °C.
- Executive summary:
A study was conducted in accordance with OPPTS 830.7550, OECD TG 107 and Regulation (EC) No 440/2008 method A.8 to determine the partition coefficient of the test item using the shake flask method. Three volume ratios octanol to water were tested - 2 to 10 mL, 1 to 10 mL and 4 to 10 mL. Appropriate volumes of water, octanol and stock solution were added to six centrifuge tubes. The tubes were gently mixed for 1 h then they were allowed to stand for another 1 h for phase separation. Carefully samples from both phases were taken and the two phases were analysed using HPLC. The partition coefficient of the test item was determined to be 482 and the log Pow was determined as 2.68.
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Study period:
- 2017
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- accepted calculation method
- Justification for type of information:
- Please refer to the QMRF and QPRF files provided under the section attached justification.
- Qualifier:
- according to guideline
- Guideline:
- other: REACH guidance on QSAR R.6
- Principles of method if other than guideline:
- Estimates the log octanol-water partition coefficient, log KOW, of chemicals using an atom/fragment contribution method.
- GLP compliance:
- no
- Type of method:
- calculation method (fragments)
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- SMILES: Oc(ccc1N(=O)(=O))cc1C(F)(F)F
- Key result
- Type:
- log Pow
- Partition coefficient:
- 2.87
- Temp.:
- 25 °C
- Conclusions:
- Using KOWWIN v1.68 the log Pow of the test item was calculated to be 2.87 at 25 °C. Molecular weight within range of training and validation set.
- Executive summary:
The logPow was calculated using KOWWIN v1.68 as part of EPISuite v4.11 from US Environmental Protection Agency.
Using KOWWIN v1.68 the log Kow of the test item was calculated to be 2.87 at 25 °C (EPI Suite, 2014).
The adequacy of a prediction depends on the following conditions:
a) the (Q)SAR model is scientifically valid: the scientific validity is established according to the OECD principles for (Q)SAR validation;
b) the (Q)SAR model is applicable to the query chemical: a (Q)SAR is applicable if the query chemical falls within the defined applicability domain of the model;
c) the (Q)SAR result is reliable: a valid (Q)SAR that is applied to a chemical falling within its applicability domain provides a reliable result;
d) the (Q)SAR model is relevant for the regulatory purpose.
For assessment and justification of these 4 requirements the QMRF and QPRF files were developed and attached to this study record.
Description of the prediction Model
The prediction model was descripted using the harmonised template for summarising and reporting key information on (Q)SAR models. For more details please refer to the attached QSAR Model Reporting Format (QMRF) file.
Assessment of estimation domain
The assessment of the estimation domain was documented in the QSAR Prediction Reporting Format file (QPRF). Please refer to the attached document for the details of the prediction and the assessment of the estimation domain.
Referenceopen allclose all
Table 1. Partition coefficient determination
Sample Name |
Solvent Ratio |
Peak Height |
HPLC µg/mL |
Dilution Factor |
Sample µg/mL |
Partition Coefficient (P) |
logP |
Mean logP |
6-0764-1X-OCT-BLK 6-0764-1X-H2O-BLK |
2.00 10.0 |
ND ND |
NA NA |
100 1.00 |
NA NA |
NA |
NA |
NA |
6-0764-1/2X-OCT-1 6-0764-1/2X-H2O-1 |
1.00 10.0 |
70821 65574 |
19.07 3.98 |
100 1 |
1907 3.98 |
479 |
2.68 |
2.64 |
6-0764- 1/2X-OCT-2 6-0764-1/2X-H20-2 |
1.00 10.0 |
61835 69165 |
16.71 4.20 |
100 1 |
1671 4.20 |
398 |
2.60 |
|
6-0764-1X-OCT-1 6-0764-1X-H2O-1 |
2.00 10.0 |
36465 33189 |
10.06 2.03 |
100 1 |
1006 2.03 |
496 |
2.70 |
2.72 |
6-0764-1X-OCT-2 6-0764-1X-H2O-2 |
2.00 10.0 |
35168 29842 |
9.72 1.83 |
100 1 |
972 1.83 |
531 |
2.73 |
|
6-0764-2X-OCT-1 6-0764-2X-H2O1 |
4.00 10.0 |
18329 13701 |
5.31 0.852 |
100 1 |
531 0.852 |
623 |
2.79 |
2.68 |
6-0764-2X-OCT-2 6-0764-2X-H2O-2 |
4.00 10.0 |
18396 24021 |
5.33 1.47 |
100 1 |
533 1.47 |
363 |
2.56 |
|
|
|
|
|
|
Mean |
482 |
2.68 |
2.68 |
Log Kow(version 1.68 estimate): 2.87
SMILES : Oc(ccc1N(=O)(=O))cc1C(F)(F)F
CHEM : 4-Nitro-3-(trifluoromethyl)phenol
MOL FOR: C7 H4 F3 N1 O3
MOL WT : 207.11
TYPE |
NUM |
LOGKOW FRAGMENT DESCRIPTION |
COEFF |
VALUE |
Frag |
1 |
C [aliphatic carbon - No H, not tert] |
0.9723 |
0.9723 |
Frag |
3 |
-F [fluorine, aliphatic attach] |
-0.0031 |
-0.0093 |
Frag |
6 |
Aromatic Carbon |
0.2940 |
1.7640 |
Frag |
1 |
-OH [hydroxy, aromatic attach] |
-0.4802 |
-0.4802 |
Frag |
1 |
-NO2 [nitro, aromatic attach] |
-0.1823 |
-0.1823 |
Factor |
1 |
Ring reaction -> -NO2 with -OH/amino/azo |
0.5777 |
0.5777 |
Const |
|
Equation Constant |
|
0.2290 |
Log Kow = 2.8712
Description of key information
The partition coefficient of the test item was determined at 23 °C to be 2.68. This value was supported with a QSAR estimation.
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 2.68
- at the temperature of:
- 23 °C
Additional information
A key study was conducted in accordance with OPPTS 830.7550, OECD TG 107 and Regulation (EC) No 440/2008 method A.8 to determine the partition coefficient of the test item using the shake flask method. Three volume ratios octanol to water were tested - 2 to 10 mL, 1 to 10 mL and 4 to 10 mL. Appropriate volumes of water, octanol and stock solution were added to six centrifuge tubes. The tubes were gently mixed for 1 h then they were allowed to stand for another 1 h for phase separation. Carefully samples from both phases were taken and the two phases were analysed using HPLC. The partition coefficient of the test item was determined to be 482 and the log Pow was determined as 2.68.
As a supporting information a QSAR estimation using KOWWIN v1.68 was performed. The logPow was estimated to be 2.87 at 25 °C.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.