Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 915-384-3 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- read-across based on grouping of substances (category approach)
- Adequacy of study:
- key study
- Study period:
- From May 10, 1999 to May 11, 1999
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- KL2 due to RA
- Justification for type of information:
- Refer to the section 13 for details on the category justification.
- Reason / purpose for cross-reference:
- read-across source
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- other: Commission Directive 87/302/EEC, Part C, Activated Sludge Respiration Inhibition Test, 1988.
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Analytical monitoring:
- no
- Vehicle:
- no
- Details on test solutions:
- - The nominal final test substance concentrations tested were 10, 32, 100, 320, and 1000 mg/L.
For the preparation of test media containing the test substance, a stock dispersion of the test substance with a nominal concentration of 5 g/L was prepared. The test substance was warmed up by means of a waterbath to about 40°C for 5 minutes to increase the fluidity and to improve the spreading properties. Then 5025 mg of test substance was dispersed in 1000 mL of deionized water by ultrasonic treatment and intense stirring. In this way a turbid but homogenous dispersion was obtained. Aliquots of this stock dispersion were mixed with synthetic wastewater and deionized water in the respective test flasks to obtain the desired concentrations. Immediately prior to the start of the test (incubation) activated sludge was added. Concentrations in excess of 1000 mg test item per liter were not tested.
Additionally, two controls (deionized water, synthetic wastewater and inoculum, without test substance) and the reference substance 3,5-dichlorophenol (positive control) at nominal concentrations of 5, 16 and 50 mg/l were tested in parallel under otherwise identical test conditions.
For test media containing the reference substance, a stock solution of 3,5-dichlorophenol was prepared according to the test guidelines: 0.5g of 3,5-dichlorophenol was dissolved in 10 mL 1 M NaOH and diluted to about 30 mL with purified water. Excess of NaOH was neutralized with 0.5 mol/L H2S04 to the point of incipient precipitation. Thereafter, the mixture was made up to one liter with purified water. The pH was determined to be pH 7.8 and the final concentration amounted to 500 mg/L. Aliquots of this 3,5-dichlorophenol stock solution were mixed with synthetic wastewater and deionized water in the respective test flasks to obtain the desired concentrations. Immediately prior to the start of the test (incubation) activated sludge was added. - Test organisms (species):
- activated sludge, domestic
- Details on inoculum:
- The study was performed with aerobic activated sludge from a wastewater treatment plant (ARA Ergolz 1, Sissach, Switzerland) treating predominantly domestic wastewater. The sludge was washed by centrifugation, the supernatant liquid phase was decanted and the solid material resuspended in tap water. This procedure was repeated twice. A homogenized aliquot of the final sludge suspension was weighed, thereafter dried and the ratio of wet sludge to its dry weight was determined. Based on this ratio, an aliquot of washed sludge was suspended in tap water to obtain a concentration equivalent to a mixed liquor suspended solids (MLSS) level of 3g per liter (on dry weight basis). During the holding of one day prior to use, the sludge was fed daily with 50 mL synthetic wastewater per liter and was kept at room temperature under continuous aeration until use. Immediately before use, the dry weight of the activated sludge was measured again in the inoculum used in the test. The pH of the activated sludge inoculum was pH 6.5.
- Test type:
- other: aerobic
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Test temperature:
- 20-21°C
- pH:
- 7.1-7.9
- Dissolved oxygen:
- > or = to 2.5 mg/L
- Nominal and measured concentrations:
- 0, 10, 32, 100, 320 and 1000 mg/L (nominal)
- Details on test conditions:
- Experimental Conditions
The inhibitory effect of the test substance on the respiration rate of aerobic wastewater microorganisms of activated sludge was investigated in a 3h respiration inhibition test. The test was performed in 1000-mL glass flasks. At the start of the test 200 mL activated sludge inoculum with a sludge concentration of 3.1 g/L dry weight (corresponding to a final MLSS level of about 1.2 g/L) was added. The sludge was added in time intervals of 15 minutes (an arbitrary but convenient interval) first to a control, then to the test solutions of the reference substance, then to the test solutions of the test substance, and finally to the second control. During the incubation period of exactly 3h all test media and the controls were continuously aerated with compressed air at a flow of approximately one liter per minute. The concentration of dissolved oxygen did not drop below 2.5 mg/L during the incubation period, and just before the measurements of the respiration rates the oxygen concentrations were at least 7.5 mg/L. The temperature in the test media, measured in one control, was 21°C at the start and 20°C at the end of the incubation period. The following nominal concentrations of test substance: 10, 32, 100, 320, and 1000 mg/L. In addition, two controls and three different concentrations of the reference substance 3,5-dichlorophenol (5, 16 and 50 mg/L) were tested in parallel. - Reference substance (positive control):
- yes
- Remarks:
- 3,5-dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- oxygen consumption
- Key result
- Duration:
- 3 h
- Dose descriptor:
- other: EC20 and EC80
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Remarks:
- oxygen consumption
- Details on results:
- Up to and including the concentration of nominal 1000 mg/L, the test substance had no inhibitory effect on the respiration rate of activated sludge after the incubation period of three hours. The respiration rates were in the range of -9.2% to -17.8% compared to the controls (negative values: enhanced respiration rates compared to the controls). Thus, the 3h EC20, EC50 and EC80 of the test substance to activated sludge microorganisms could not be calculated, but were clearly higher than 1000 mg/L.
- Results with reference substance (positive control):
- The 3h EC50 of the reference substance 3,5-dichlorophenol (positive control) was calculated to be 7.0 mg/L (95% confidence limits were not calculable). Thus, the EC50 of the reference substance was in the accepted range of 5-30 mg/L and confirmed the suitability of the used activated sludge.
- Validity criteria fulfilled:
- yes
- Conclusions:
- Under the study conditions, the 3 h EC50 of the read across substance to microorganisms was determined to be >1000 mg/L (nominal).
- Executive summary:
A study was conducted to determine the toxicity of the read across substance, isoC18 MIPA (100% active), to microorganisms according to OECD Guideline 209 and Commission Directive 87/302/EEC, Part C, in compliance with GLP. Activated sludge was exposed to the test substance at nominal concentrations of 0, 10, 32, 100, 320 and 1000 mg/L for 3 h. In addition, two controls and three different concentrations of the reference substance 3,5 -dichlorophenol (5, 16 and 50 mg/L) were tested. The respiration rate (oxygen consumption) of the aerobic activated sludge fed with standard amounts of synthetic wastewater was measured. The inhibitory effect of the test substance was expressed as a percentage of the mean respiration rate of the controls. Up to and including the nominal concentration of 1000 mg/L, the test substance had no inhibitory effect on the respiration rate of activated sludge after the incubation period of 3 h. The respiration rates were in the range of -9.2 to ‑17.8% compared to the controls. The 3 h EC50 of the reference substance 3,5 -dichlorophenol (positive control) was calculated to be 7.0 mg/L and therefore was in the accepted range of 5 -30 mg/L, confirming the suitability of the used activated sludge. Under the study conditions, the 3 h EC50 of the test substance to microorganisms was determined to be >1000 mg/L (nominal) (Batscher, 1999). Based on the results of the read across study, the test substance is also expected to have similar toxicity to microorganisms.
Reference
None.
Description of key information
Key value for chemical safety assessment
- EC50 for microorganisms:
- 1 000 mg/L
Additional information
A study was conducted to determine the toxicity of the read across substance, isoC18 MIPA (100% active), to microorganisms according to OECD Guideline 209 and Commission Directive 87/302/EEC, Part C, in compliance with GLP. Activated sludge was exposed to the test substance at nominal concentrations of 0, 10, 32, 100, 320 and 1000 mg/L for 3 h. In addition, two controls and three different concentrations of the reference substance 3,5 -dichlorophenol (5, 16 and 50 mg/L) were tested. The respiration rate (oxygen consumption) of the aerobic activated sludge fed with standard amounts of synthetic wastewater was measured. The inhibitory effect of the test substance was expressed as a percentage of the mean respiration rate of the controls. Up to and including the nominal concentration of 1000 mg/L, the test substance had no inhibitory effect on the respiration rate of activated sludge after the incubation period of 3 h. The respiration rates were in the range of -9.2 to ‑17.8% compared to the controls. The 3 h EC50 of the reference substance 3,5 -dichlorophenol (positive control) was calculated to be 7.0 mg/L and therefore was in the accepted range of 5 -30 mg/L, confirming the suitability of the used activated sludge. Under the study conditions, the 3 h EC50 of the test substance to microorganisms was determined to be >1000 mg/L (nominal) (Batscher, 1999).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.