Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-01-09 to 2018-04-17
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
GLP compliance:
no
Type of method:
equilibrium method closed cup
Key result
Flash point:
48.5 °C
Atm. press.:
1 013 hPa

The following tables show the results of the measurements at temperatures where ignition (+) was detected and where not (-).

Table 1: Results of the preliminary test

Test item / mL

Starting temperature / °C

Temperature / °C

Ignition +/-

2

20.0

50.0

+

2

20.0

49.5

+

2

29.5

54.5

+

Table 2: Results of the main test

Test item / mL

Temperature / °C

Ignitioin +/-

Barometric pressure / hPa

2

54.5

+

1007.6

2

49.5

+

1007.6

2

44.5

-

1007.6

2

45.5

-

1007.6

2

46.5

-

1007.6

2

47.5

-

1007.6

2

48.5

+

1007.6

2

48.0

-

1007.6

2

48.5

+

1007.6

2

48.0

-

1007.6

2

48.5

+

1007.6

2

48.0

-

1007.6

The lowest flash point corrected to 1013 hPa rounded down with an accuracy of 0.5 °C is 48.5 °C.

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The flash point of the test item was 48.5 °C under atmospheric conditions (1013 hPa).
Executive summary:

The flash point of the test item was determined according to EC Method A.9. Based on results of the main test, the lowest flash point corrected to 1013 hPa rounded down with an accuracy of 0.5 °C was 48.5 °C. Based on criteria set in the CLP regulation the test item is a flammable liquid (Category 3).

Description of key information

The flash point of the test item was determined according to EC Method A.9. Based on results of the main test, the lowest flash point corrected to 1013 hPa rounded down with an accuracy of 0.5 °C was 48.5 °C. Based on criteria set in the CLP regulation the test item is a flammable liquid (Category 3).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
48.5 °C

Additional information