Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Endpoint summary
Administrative data
Description of key information
Based on the results of the in vitro studies, the test substance, ‘mono- C16 PSE and C16 -OH’, is considered to be non-irritant to skin and corrosive to the eyes.
Key value for chemical safety assessment
Skin irritation / corrosion
Link to relevant study records
- Endpoint:
- skin irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From May 16, 2017 to June 16, 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 439 (In Vitro Skin Irritation: Reconstructed Human Epidermis Test Method)
- Deviations:
- yes
- Remarks:
- see "Principles of method if other than guideline"
- Principles of method if other than guideline:
- Optical Density (OD) values obtained with blanks were higher than 0.1 (0.191) causing a deviation from Acceptance Criteria 4. However, this SOP and guideline deviation was not considered to have affected the integrity or interpretation of the results as no equivocal results were obtained.
- GLP compliance:
- yes (incl. QA statement)
- Test system:
- human skin model
- Remarks:
- MatTek EpiDermTM tissue model EPI-200
- Justification for test system used:
- Initially the predictive capacity of the modified EpiDerm™ Skin Irritation Test (SIT) test method, using MatTek EpiDermTM tissue model EPI-200, underwent full prospective validation from 2003-2007. The test method components of this method were used to define the essential test methods components of the original and updated ECVAM Performance Standards (PS). A modification of the original EpiDerm™ SIT was validated using the original ECVAM PS in 2008. In 2008, ESAC concluded that the Modified EpiDerm™ SIT has sufficient accuracy and reliability for prediction of R38 skin irritating and no-label (non-skin irritating) test substances.
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- Test system:
The reconstructed human epidermal model EpiDermTM (EPI-200-MatTek Corporation) consists of normal human-derived epidermal keratinocytes which have been cultured to form a multi-layered highly differentiated model of the human epidermis. It consists of organised basal, spinous and granular layers and a multi-layered stratum corneum containing intercellular lamellar lipid layers arranged in patterns analogous to those found in vivo.
Characterisation of the test system:
MatTek’s EpiDermTM model has been extensively characterised for multiple parameters including morphology, tissue viability, skin barrier function and sterility. QC results for the specific lot of models received (Lot# 25819) were checked in-house for MatTek acceptance ranges with the following outcome:
- Morphology - PASS
- Tissue viability - PASS
- Skin barrier function (ET50 value for 1 % Triton X-100) where ET50 is the time taken for 1 % Triton X-100 to reduce the viability of the skin model to 50 % relative to the negative control) - PASS
- Sterility testing showed no contamination during long term antibiotic and antimycotic free culture - PASS - Control samples:
- yes, concurrent negative control
- yes, concurrent positive control
- Amount/concentration applied:
- 25 mg (nominal) of the neat test substance after pre-wetting tissues with 25 μL DPBS (Sterile Dulbecco’s Phosphate Buffered Saline).
- Duration of treatment / exposure:
- 60 minutes (25 minutes at room temperature and 35 minutes at 37°C, 5 % CO2).
- Duration of post-treatment incubation (if applicable):
- 42 h post-treatment incubation.
- Number of replicates:
- 3 replicates for test substance, negative and positive control.
- Irritation / corrosion parameter:
- % tissue viability
- Value:
- 89.1
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Other effects / acceptance of results:
- - Prior to the study, the required compatibility checks (as per SOP L0029) confirmed that the test substance did not interfere with MTT and no water colouration was observed.
- The test substance did reduce the viability below 50 % and should be considered as irritant to the skin.
All acceptance criteria were met with the exception of 1 criterion:
- The mean OD570 of the negative control (treated with DPBS) tissues is ≥0.8 and ≤2.8.
Result: 1.777
- The mean of the positive control relative percentage viability must be ≤20 % of the mean of the negative controls.
Result: 3.8 %
- The standard deviation of OD values for triplicate skin models in each experimental condition must be <18 %.
Results:
NC: 5 %
PC: 0.72 %
Test substance: 16.17 %
- The mean OD of the 6 wells containing extraction solvent alone (blanks) should be ≤0.1.
Result: 0.191
Optical Density (OD) values obtained with blanks were higher than 0.1 (0.191) causing a deviation from Acceptance Criteria 4. However, the spectrophotometer was fully validated and had passed all required tests. The OD values for blanks observed in this study are consistent with historical data using this spectrophotometer in the laboratory and meet our current internal acceptance criteria of blank OD values <0.194 (mean of historical data, based on blanks obtained during the last 66 studies), therefore this is not considered to be an issue in the interpretation of this study data.
This SOP and guideline deviation was not considered to have affected the integrity or interpretation of the results as no equivocal results were obtained. - Interpretation of results:
- other: CLP criteria not met
- Remarks:
- non-irritant to skin
- Conclusions:
- Under the study conditions, the test substance was determined to be non-irritant to the skin.
- Executive summary:
An in vitro study was conducted to determine the skin irritation potential of the test substance, 'mono- C16 PSE and C16 -OH' (purity not specified), in Reconstructed Human Epidermis (RHE) cells, according to OECD Guideline 439, in compliance with GLP. Three tissues of the human skin model EpiDermTM were treated with the test substance, positive or negative control for 60 minutes (25 minutes at room temperature and 35 minutes at 37°C, 5 % CO2, 95 % RH) and 42 h post incubation period. Test was performed with 3 replicates for each type of treatment. Tissues were first pre-wetted with 25 μL DPBS (Sterile Dulbecco’s Phosphate Buffered Saline), subsequently 25 mg (nominal) of the neat test substance was applied. 30 μL of DPBS was used as negative control and 5% of sodium dodecyl sulphate as positive control. Viability of the tissues was assessed in MTT test and compared to the negative control. The percentage of viability obtained with the test substance was 89.1%, which is well above the irritant limit of 50%. The study met all the validity criteria. Under the study conditions, the test substance was determined to be non-irritant to the skin (XCellR8, 2017).
- Endpoint:
- skin corrosion: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From November 24, 2004 to December 02, 2004
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- equivalent or similar to guideline
- Guideline:
- OECD Guideline 435 (In Vitro Membrane Barrier Test Method for Skin Corrosion)
- Version / remarks:
- Report from 2004 before Guideline implementation
- Deviations:
- no
- GLP compliance:
- not specified
- Specific details on test material used for the study:
- Appearance: white powder
- Test system:
- artificial membrane barrier model
- Remarks:
- Corrositex test
- Vehicle:
- unchanged (no vehicle)
- Details on test system:
- The Corrositex test is a standardized and reproducible method that can be employed to determine the potential corrosivity and the packing group classification of specified categories of chemical compounds under the hazardous materials transportation regulations administrated by the U.S. Department of Transportation (DOT) and international dangerous goods codes. The Corrositex test predicts the in vitro corrosive potential of a chemical compound or mixture by using as an endpoint the amount of time it takes for chemical to permeate through or destroy a synthetic biobarrier. A color change in a proprietary liquid Chemical Detection System (CDS) is used to indicate that the chemical has passed through the biobarrier.
- Control samples:
- yes, concurrent positive control
- Amount/concentration applied:
- neat test substance
- Duration of treatment / exposure:
- 240 minutes
- Number of replicates:
- 4
- Amount / concentration applied:
- 100 %
- Irritation / corrosion parameter:
- penetration time (in minutes)
- Run / experiment:
- All 4 replicates
- Value:
- > 65
- Vehicle controls validity:
- not applicable
- Negative controls validity:
- not applicable
- Positive controls validity:
- not applicable
- Remarks on result:
- other: non-corrosive
- Other effects / acceptance of results:
- Corrositex time [minutes] for all 4 replicates: >65 min
pH measured in 10 % aqueous test solution: 2.1
Color in tube A: yellow
pH in measure in tube A 6.4
Category: 2
Packing group: non-corrosive
The results of the study indicated that the sample was compatible with Corrositex system and was determined to be a category 2 sample. The results obtained from the evaluation of four replicate samples were consistent, demonstrating that a mean time of >65 minutes was required to destroy the synthetic biobarriers. This findings lead to the classification of the test substance as a non-corrosive material. - Interpretation of results:
- other: CLP criteria not met
- Remarks:
- non-corrosive
- Conclusions:
- Under the study conditions, the test substance is classified as a non-corrosive material according to U.S department of transport and international dangerous goods codes.
- Executive summary:
An in vitro study was conducted to determine the in skin corrosion potential and packing group designation of the test substance, 'mono- C16 PSE and C16-OH' (purity not specified), according to Corrositex test method. The Corrositex test predicts the in vitro corrosive potential of a chemical compound or mixture by using as an endpoint, the amount of time it takes for chemical to permeate through or destroy a synthetic biobarrier. A color change in a proprietary liquid Chemical Detection System (CDS) is used to indicate that the chemical has passed through the biobarrier. Four samples were examined with application of neat test substance (100%). The test substance was compatible with Corrositex system. The results obtained from the evaluation of four replicate samples were consistent, demonstrating that a mean time of >65 minutes was required to destroy the synthetic biobarriers. Under the study conditions, the test substance is classified as a non-corrosive material according to U.S department of transport and international dangerous goods codes (MBRL, 2004).
Referenceopen allclose all
Endpoint conclusion
- Endpoint conclusion:
- no adverse effect observed (not irritating)
Eye irritation
Link to relevant study records
- Endpoint:
- eye irritation: in vitro / ex vivo
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- July 04, 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 437 (Bovine Corneal Opacity and Permeability Test Method for Identifying i) Chemicals Inducing Serious Eye Damage and ii) Chemicals Not Requiring Classification for Eye Irritation or Serious Eye Damage)
- Deviations:
- yes
- Remarks:
- Deviations were considered to have not affected the integrity or validity of the study
- Qualifier:
- according to guideline
- Guideline:
- EU method B.47 (Bovine corneal opacity and permeability test method for identifying ocular corrosives and severe irritants)
- Deviations:
- yes
- Remarks:
- Deviations were considered to have not affected the integrity or validity of the study
- GLP compliance:
- yes (incl. QA statement)
- Species:
- cattle
- Strain:
- not specified
- Details on test animals or tissues and environmental conditions:
- Source of Bovine Eyes
Eyes from adult cattle (typically 12 to 60 months old) were obtained from a local abattoir as a by-product from freshly slaughtered animals. The eyes were excised by an abattoir employee after slaughter, and were placed in Hanks’ Balanced Salt Solution (HBSS) supplemented with antibiotics (penicillin at 100 IU/mL and streptomycin at 100 µg/mL). They were transported to the test facility over ice packs on the same day of slaughter. The corneas were prepared immediately on arrival. - Vehicle:
- physiological saline
- Controls:
- yes, concurrent positive control
- yes, concurrent negative control
- Amount / concentration applied:
- 0.75 mL test substance or reference substances (Positive control: 20% w/v imidazole solution in sodium chloride 0.9% w/v, Negative control: Sodium chloride 0.9% w/v)
- Duration of treatment / exposure:
- At 32 ± 1 ºC for 240 minutes
- Duration of post- treatment incubation (in vitro):
- At 32 ± 1 ºC for 90 minutes for permeablity assessment
- Number of animals or in vitro replicates:
- Three corneas to each test substance and reference substances
- Details on study design:
- Preparation of corneas
All eyes were macroscopically examined before and after dissection. Only corneas free of damage were used. The cornea from each selected eye was removed leaving a 2 to 3 mm rim of sclera to facilitate handling. The iris and lens were peeled away from the cornea. The isolated corneas were immersed in a dish containing HBSS until they were mounted in Bovine Corneal Opacity and Permeability (BCOP) holders. The anterior and posterior chambers of each BCOP holder were filled with complete Eagle’s Minimum Essential Medium (EMEM) without phenol red and plugged. The holders were incubated at 32 ± 1 ºC for 70 minutes. At the end of the incubation period each cornea was examined for defects. Only corneas free of damage were used.
Selection of corneas and opacity reading
The medium from both chambers of each holder was replaced with fresh complete EMEM. A pre‑treatment opacity reading was taken for each cornea using a calibrated opacitometer.Three corneas were randomly allocated to the negative control. Three corneas were also allocated to the test substance and three corneas to the positive control substance.
Treatment of corneas
The EMEM was removed from the anterior chamber of the BCOP holder and 0.75 mL of the test substance preparation or control substances were applied to the appropriate corneas. The holders were gently tilted back and forth to ensure a uniform application of the substance over the entire cornea. Each holder was incubated, anterior chamber uppermost, at 32 ± 1 ºC for 240 minutes. At the end of the exposure period the test substance and control substances were removed from the anterior chamber and the cornea was rinsed three times with fresh complete EMEM containing phenol red before a final rinse with complete EMEM without phenol red. The anterior chamber was refilled with fresh complete EMEM without phenol red. A post‑treatment opacity reading was taken and each cornea was visually observed. The negative and positive control data was shared with Envigo study number NX25RF and LM55TK.
Application of sodium fluorescein
Following the opacity measurement the permeability of the corneas to sodium fluorescein was evaluated. The medium from the anterior chamber was removed and replaced with 1 mL of sodium fluorescein solution (5 mg/mL). The dosing holes were plugged and the holders incubated, anterior chamber uppermost, at 32 ± 1 ºC for 90 minutes.
Permeability determinations
After incubation the medium in the posterior chamber of each holder was decanted and retained.360 µL of media representing each cornea was dispensed into the appropriate wells of a pre‑labeled 96‑well plate. The optical density was measured (quantitative viability analysis) at 492 nm (without a reference filter) using the Labtech LT-4500 microplate reader.
Histopathology
The corneas were retained after testing for possible conduct of histopathology. Each cornea was placed into a pre‑labeled tissue cassette fitted with a histology sponge to protect the endothelial surface. The cassette was immersed in 10% neutral buffered formalin. In this study histopathology was not required.
Data evaluation
Results from the two test method endpoints, opacity and permeability, were combined in an empirically derived formula to generate an In Vitro Irritancy Score.
Opacity measurement
The change in opacity for each cornea (including the negative control) was calculated by subtracting the initial opacity reading from the final opacity reading. These values were then corrected by subtracting the average change in opacity observed for the negative control corneas. The mean opacity value of each treatment group was then calculated by averaging the corrected opacity values of each cornea for that treatment group.
Permeability measurement
The corrected OD492 was calculated by subtracting the mean OD492 of the negative control corneas from the OD492 value of each treated cornea. The OD492 value of each treatment group was calculated by averaging the corrected OD492 values of the treated corneas for the treatment group.
In Vitro irritancy score
The following formula was used to determine the In Vitro Irritancy Score:
In Vitro Irritancy Score = mean opacity value + (15 x mean permeability OD492 value)
Additionally, the opacity and permeability values were evaluated independently to determine whether the test substance induced a response through only one of the two endpoints.
Visual observation
The condition of the cornea was visually assessed post treatment. - Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Test substance
- Value:
- ca. 77
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Positive control
- Value:
- ca. 127
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- positive indication of irritation
- Irritation parameter:
- in vitro irritation score
- Run / experiment:
- Negative control
- Value:
- ca. 1.4
- Vehicle controls validity:
- valid
- Negative controls validity:
- valid
- Positive controls validity:
- valid
- Remarks on result:
- no indication of irritation
- Other effects / acceptance of results:
- The positive control In Vitro Irritancy Score was above the range of 65.1 to 123.3. The positive control acceptance criterion was therefore not satisfied. This was reported as a deviation. The negative control gave opacity of ≤2.4 and permeability ≤0.072. The negative control acceptance criteria were therefore satisfied.
- Interpretation of results:
- other: Category 1 (irreversible effects on the eye) based on EU CLP criteria
- Conclusions:
- Under the study conditions, the test substance was considered to be corrosive.
- Executive summary:
A study was conducted to determine the eye irritation potential of the test substance, 'mono- C16 PSE and C16-OH' (100 %), using Bovine corneal Opacity Test (BCOP), according to OECD Guideline 437 and EU Method B.47, in compliance with GLP. Eyes from adult cattle (typically 12 to 60 months old) were obtained from a local abattoir as a by-product from freshly slaughtered animals. Preparation, selection and opacity reading of the corneas were performed as per guideline. Prepared corneas in triplicates were treated with each, test substance (20% w/v in sodium chloride 0.9% w/v), negative control (Sodium chloride 0.9% w/v) and positive control (20% w/v Imidazole solution in sodium chloride 0.9% w/v) substances at 32 ± 1ºC for 240 minutes. At the end of the exposure period the test substance and control substances were removed from the anterior chamber and the cornea was rinsed three times with fresh complete Eagle’sMinimum Essential Medium (EMEM) containing phenol red before a final rinse with complete EMEM without phenol red. A post treatment opacity reading was taken and each cornea was visually observed. The negative and positive control data was shared with Envigo study number LM55TK and NX25RF. Following the opacity measurement the permeability of the corneas to sodium fluorescein was evaluated. The medium from the anterior chamber was removed and replaced with 1 mL of sodium fluorescein solution (5 mg/mL). The dosing holes were plugged and the holders incubated, anterior chamber uppermost, at 32 ± 1ºC for 90 minutes. The two endpoints, decreased light transmission through the cornea (opacity) and increased passage of sodium fluorescein dye through the cornea (permeability) were combined in an empirically derived formula to generate an In Vitro Irritancy Score (IVIS). The positive control group had an overall IVIS of 127.0, which was marginally higher than the criteria range set for an acceptable test. However, as the score was only marginally exceeded, the study author decided that this result was acceptable as the positive control group was still providing its intended function, which is to show the sensitivity of the test system to a known ocular irritant. The negative control gave opacity of ≤2.4 and permeability ≤0.072, the negative control acceptance criteria were therefore satisfied. The test substance IVIS score obtained was 77, which is well above the threshold for corrosive classification. Under the study conditions, the test substance was considered to be corrosive and classified as Category 1 or Eye Damage 1 - H318: causes serious eye damage, according to UN GHS or EU CLP (Envigo, 2018).
Reference
Results
Corneal Opacity and Permeability measurement
Individual and mean corneal opacity measurements and individual and mean corneal permeability measurements are given in following table 1:
Treatment |
Cornea number |
Opacity |
Permeability (OD492) |
In Vitro Irritancy Score |
||||
Pre-Treatment |
Post-Treatment |
Post-Treatment-Pre‑Treatment |
Corrected Value |
|
Corrected Value |
|||
Negative ControlÅ |
1 |
3 |
4 |
1 |
|
0.012 |
|
|
2 |
3 |
4 |
1 |
|
0.000 |
|
|
|
3 |
2 |
4 |
2 |
|
0.000 |
|
|
|
Mean |
|
|
1.3 |
|
0.004 |
|
1.4 |
|
Positive |
4 |
2 |
105 |
103 |
101.7 |
3.965 |
3.961 |
|
5 |
2 |
88 |
86 |
84.7 |
1.895 |
1.891 |
|
|
6 |
2 |
83 |
81 |
79.7 |
1.820 |
1.816 |
|
|
Mean |
|
|
|
88.7 |
|
2.556 |
127.0 |
|
Test Substance |
10 |
2 |
74 |
72 |
70.7 |
0.007 |
0.003 |
|
11 |
2 |
82 |
80 |
78.7 |
0.000 |
0.000 |
|
|
12 |
3 |
86 |
83 |
81.7 |
0.000 |
0.000 |
|
|
Mean |
|
|
|
77.0 |
|
0.001 |
77.0 |
Corneal Epithelium Condition
The condition of each cornea is given in below table 2:
Treatment |
Cornea number |
observation |
Negative Control* |
1 |
Clear |
2 |
Clear |
|
3 |
Clear |
|
Positive Control* |
4 |
Cloudy |
5 |
Cloudy |
|
6 |
Cloudy |
|
Test Substance |
10 |
Cloudy |
11 |
Cloudy |
|
12 |
Cloudy |
* = Control data shared with Envigo study number NX25RF and LM55TK
The corneas treated with the test substance were cloudy post treatment. The corneas treated with the negative control substance were clear post treatment. The corneas treated with the positive control substance were cloudy post treatment.
In Vitro Irritancy Score
The In Vitro irritancy scores are summarized as follows:
Treatment |
In Vitro Irritancy Score |
Test Substance |
77.0 |
Negative Control |
1.4 |
Positive Control |
127.0 |
Criteria for an Acceptable Test
The positive control In Vitro Irritancy Score was above the range of 65.1 to 123.3. The positive control acceptance criterion was therefore not satisfied. This is reported as a deviation.
The negative control gave opacity of ≤2.4 and permeability ≤0.072. The negative control acceptance criteria were therefore satisfied.
Conclusion
Category 1. UN GHS or EU CLP Causes serious eye damage
Endpoint conclusion
- Endpoint conclusion:
- adverse effect observed (irritating)
Respiratory irritation
Endpoint conclusion
- Endpoint conclusion:
- no study available
Additional information
Skin:
Study 1: An in vitro study was conducted to determine the in skin corrosion potential and packing group designation of the test substance, mono- C16 PSE + C16-OH (Purity not specified), according to Corrositex test method. The Corrositex test predicts the in vitro corrosive potential of a chemical compound or mixture by using as an endpoint, the amount of time it takes for chemical to permeate through or destroy a synthetic biobarrier. A color change in a proprietary liquid Chemical Detection System (CDS) is used to indicate that the chemical has passed through the biobarrier. Four samples were examined with application of neat test substance (100%). The test substance was compatible with Corrositex system. The results obtained from the evaluation of four replicate samples were consistent, demonstrating that a mean time of >65 minutes was required to destroy the synthetic biobarriers. Under the study conditions, the test substance is classified as a non-corrosive material according to U.S department of transport and international dangerous goods codes (MBRL, 2004).
Study 2: An in vitro study was conducted to determine the skin irritation potential of the test substance, 'mono- C16 PSE and C16 -OH' (purity not specified), in Reconstructed Human Epidermis (RHE) cells, according to OECD Guideline 439, in compliance with GLP. Three tissues of the human skin model EpiDermTM were treated with the test substance, positive or negative control for 60 minutes (25 minutes at room temperature and 35 minutes at 37°C, 5 % CO2, 95 % RH) and 42 h post incubation period. Test was performed with 3 replicates for each type of treatment. Tissues were first pre-wetted with 25 μL DPBS (Sterile Dulbecco’s Phosphate Buffered Saline), subsequently 25 mg (nominal) of the neat test substance was applied. 30 μL of DPBS was used as negative control and 5% of sodium dodecyl sulphate as positive control. Viability of the tissues was assessed in MTT test and compared to the negative control. The percentage of viability obtained with the test substance was 89.1%, which is well above the irritant limit of 50%. The study met all the validity criteria. Under the study conditions, the test substance was determined to be non-irritant to the skin (XCellR8, 2017).
Eye:
A study was conducted to determine the eye irritation potential of the test substance, 'mono- C16 PSE and C16-OH' (100 %),using Bovine corneal Opacity Test (BCOP), according to OECD Guideline 437 and EU Method B.47, in compliance with GLP. Eyes from adult cattle (typically 12 to 60 months old) were obtained from a local abattoir as a by-product from freshly slaughtered animals. Preparation, selection and opacity reading of the corneas were performed as per guideline. Prepared corneas in triplicates were treated with each, test substance (20% w/v in sodium chloride 0.9% w/v), negative control (Sodium chloride 0.9% w/v) and positive control (20% w/v Imidazole solution in sodium chloride 0.9% w/v) substances at 32 ± 1ºC for 240 minutes. At the end of the exposure period the test substance and control substances were removed from the anterior chamber and the cornea was rinsed three times with fresh completeEagle’sMinimum Essential Medium (EMEM) containing phenol red before a final rinse with complete EMEM without phenol red. A post treatment opacity reading was taken and each cornea was visually observed. The negative and positive control data was shared with Envigo study number LM55TK and NX25RF. Following the opacity measurement the permeability of the corneas to sodium fluorescein was evaluated. The medium from the anterior chamber was removed and replaced with 1 mL of sodium fluorescein solution (5 mg/mL). The dosing holes were plugged and the holders incubated, anterior chamber uppermost, at 32 ± 1ºC for 90 minutes. The two endpoints, decreased light transmission through the cornea (opacity) and increased passage of sodium fluorescein dye through the cornea (permeability) were combined in an empirically derived formula to generate an In Vitro Irritancy Score (IVIS). The positive control group had an overall IVIS of 127.0, which was marginally higher than the criteria range set for an acceptable test. However, as the score was only marginally exceeded, the study author decided that this result was acceptable as the positive control group was still providing its intended function, which is to show the sensitivity of the test system to a known ocular irritant. The negative control gave opacity of ≤2.4 and permeability ≤0.072, the negative control acceptance criteria were therefore satisfied. The test substance IVIS score obtained was 77, which is well above the threshold for corrosive classification. Under the study conditions, the test substance was considered to be corrosive and classified as Category 1 or Eye Damahge 1 - H318: causes serious eye damage, according to UN GHS or EU CLP (Envigo, 2018).
Justification for classification or non-classification
Skin irritation:
Based on the results of in vitro skin irritation/corrosion studies, the test substance, ‘mono- C16 PSE and C16 -OH', does not warrant classification for skin irritation according to the EU CLP criteria (Regulation 1272/2008/EC).
Eye irritation:
Based on the results of read across in vitro eye irritation study (BCOP), the ‘mono- C16 PSE and C16 -OH’ warrants an ‘Eye damage 1: H318- causes serious eye damage’ classification according to the EU CLP criteria (Regulation EC 1272/2008). Labelling for this endpoint should include “Danger” as signal word.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.