Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Flash point:
128.5 °C
Atm. press.:
101.2 kPa
Interpretation of results:
GHS criteria not met
Conclusions:
The Pensky-Martens closed cup flash point test method applied to Isophoronediamine-cresyl glycidyl ether adduct provided flash point temperature to be 128.5 C at atmospheric pressure.
Executive summary:

The Pensky-Martens closed cup flash point test method applied to  Isophoronediamine-cresyl glycidyl ether adduct provided flash point temperature to be 128.5 C at atmospheric pressure.

Description of key information

The Pensky-Martens closed cup flash point test method applied to  Isophoronediamine-cresyl glycidyl ether adduct provided flash point temperature to be 128.5 C at atmospheric pressure.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
128.5 °C

Additional information