Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
water solubility
Type of information:
experimental study
Adequacy of study:
key study
Study period:
5 April - 16 May, 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 105 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.6 (Water Solubility)
Deviations:
no
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7840 (Water Solubility)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
flask method

Test material

Constituent 1
Reference substance name:
Acetamide, N-(2,4-dinitrophenyl)-, reaction products with 1-methyl-2,4-dinitrobenzene and sodium sulfide (Na2(Sx)), leuco derivatives
EC Number:
288-896-1
EC Name:
Acetamide, N-(2,4-dinitrophenyl)-, reaction products with 1-methyl-2,4-dinitrobenzene and sodium sulfide (Na2(Sx)), leuco derivatives
Cas Number:
85940-08-5
Molecular formula:
not applicable
IUPAC Name:
Reaction product of N-(2,4-dinitrophenyl)acetamide with 1-methyl-2,4-dinitrobenzene and polysulfide, leuco derivatives
Test material form:
solid: particulate/powder
Details on test material:
Test item: Leuco Sulphur Brown 46
Appearance: Brown powder
CAS No: 85940-08-5

Results and discussion

Water solubility
Key result
Water solubility:
16.5 mg/L
Conc. based on:
test mat.
Loading of aqueous phase:
2 500 mg/L
Incubation duration:
>= 24 - <= 72 h
Temp.:
20 °C
pH:
>= 7.06 - <= 7.41

Any other information on results incl. tables

Results of the determination of Leuco Sulphur Brown 46 concentrations

Sampling time

Measured concentration of Leuco Sulphur Brown 46 (mg/L )

Measured pH

Test vessels

Mean with the 95% confidence intervals

After 24h

17.0

17.9 ± 2.8

7.06

17.7

7.17

19.1

7.17

After 48h

16.6

16.0 ± 1.5

7.32

15.8

7.33

15.4

7.37


Results of the determination of Leuco Sulphur Brown 46 concentrations (continued)

Sampling time

Measured concentration of Leuco Sulphur Brown 46 (mg/L )

Measured pH

Test vessels

Mean

After 72h

16.1

15.7 ± 1.3

7.41

15.1

7.44

15.8

7.43

Solubility ofthe test item (mg/L)

16.5 ± 0.97

16.5 ± 3.0

-

RSD%

8

7

-

Ultra-pure water

< LOQ

8.05

Applicant's summary and conclusion

Conclusions:
The water solubility of the test item was determined to be 16.5 ± 3.0 mg/L (95% confidence interval) at 20 °C ± 1 °C using the shake-flask method for the performance.
Executive summary:

In the course of this study the water solubility of the test item was determined at 20 °C ± 1 °C using the shake-flask method for the performance of the main test. The water solubility was determined to be 16.5 ± 3.0 mg/L (95% confidence interval).