Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
- Principle of test: Laser diffraction using HELOS (H1591) and Rodos
GLP compliance:
not specified
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Mass median aerodynamic diameter:
>= 2.7 - <= 2.78 µm
Percentile:
D10
Mean:
0.76 µm
St. dev.:
0
Key result
Percentile:
D50
Mean:
2.75 µm
St. dev.:
0.03
Percentile:
D90
Mean:
10.72 µm
St. dev.:
0.34
Conclusions:
The particle size distribution was tested using laser diffraction under standardised test condition. The particle size is D50 = 2.75 µm.

Description of key information

The particle size distribution was tested using laser diffraction under standardised test condition. The particle size is D50 = 2.75 µm.

Additional information