Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 259-952-2 | CAS number: 56038-13-2
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to aquatic algae and cyanobacteria
Administrative data
Link to relevant study record(s)
- Endpoint:
- toxicity to aquatic algae and cyanobacteria
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1986-05-09 to 1987-01-15
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- comparable to guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 201 (Alga, Growth Inhibition Test)
- Version / remarks:
- version: adopted 7 June 1984
- Deviations:
- yes
- Remarks:
- extension of test duration to 96h
- GLP compliance:
- yes
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: KL/5/31
- Purity test date: 99.2%
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: in the dark in the deep freeze in the container in which it was received - Analytical monitoring:
- yes
- Details on sampling:
- - Concentrations: all test concentrations and the control
- Sampling method: At the start and finish of the test, samples were taken of each test solution, using excess remaining after filling the test vessels and one of the test replicates, respectively. - Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method: A stock solution of the test substance in distilled water was prepared. Each test solution was prepared by the addition of aliquots of stock solution to sterile culture medium, with equalising additions of distilled water to a volume of 800 mL.
- Controls: culture medium only - Test organisms (species):
- Pseudokirchneriella subcapitata (previous names: Raphidocelis subcapitata, Selenastrum capricornutum)
- Details on test organisms:
- TEST ORGANISM
- Common name: Green alga
- Strain: Selenastrum capricornutum Printz, ATCC 22662
ACCLIMATION
- Culturing media and conditions (same as test or not): same as test - Test type:
- static
- Water media type:
- other: according to Miler et al 1978
- Limit test:
- no
- Total exposure duration:
- 96 h
- Test temperature:
- 23.7 - 24.2°C
- pH:
- test start: 7.2 - 7.3
test end: 9.5- 9.9 - Nominal and measured concentrations:
- nominal: control, 180, 320, 560, 1000 and 1800 mg/L
measured: <18, 170, 315, 540, 930, 1760 mg/L - Details on test conditions:
- TEST SYSTEM
- Test vessel: borosilicate glass conical flasks of 250mL nominal capacity with polyurethane foam bungs
- Material, size, headspace, fill volume: each flask contained 100 mL of test solution
- Initial cells density: 1.0 x 10^4 cells/mL
- Control end cells density: mean: 291.83 x 10^4 cells/mL
- No. of vessels per concentration (replicates): 3
- No. of vessels per control (replicates): 6
GROWTH MEDIUM
- Standard medium used: yes
OTHER TEST CONDITIONS
- Sterile test conditions: yes
- Photoperiod: continuous illumination
- Light intensity and quality: 7550 Lux; 850 microwatts/cm²
- Other: shaking at 100 rpm
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
- Determination of cell concentrations: Coulter Counter Model ZB - Reference substance (positive control):
- no
- Key result
- Duration:
- 96 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 800 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- growth rate
- Duration:
- 96 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 800 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- biomass
- Duration:
- 96 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 1 800 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- other: growth rate and biomass
- Details on results:
- The measured concentrations of the test substance at the start and finish ranged from 93% to 100% of the nominal values, and therefore the nominal concentrations were used to calculate the results.
- Reported statistics and error estimates:
- Dunnett's procedure was used to identify significant differences (P < 0.5) from the control.
- Validity criteria fulfilled:
- not specified
- Conclusions:
- The toxicity of the test item on the green algae Selenastrum capricornutum was determined in a GLP study according to OECD 201 except the extension of test duration to 96 h. The 96-h EC50 was determined to be >1800 mg/L (nominal).
Reference
Algal cell densities
nominal concentration [mg/L] |
replicate | Algal cell density [x10^4 cells/mL] |
|||
day 1 | day 2 | day 3 | day 4 | ||
control | 1 | 3.30 | 18.30 | 91.80 | 289.00 |
2 | 3.73 | 20.50 | 103.00 | 310.00 | |
3 | 3.90 | 22.10 | 111.00 | 311.00 | |
4 | 3.43 | 19.50 | 95.10 | 286.00 | |
5 | 3.45 | 19.20 | 95.20 | 265.00 | |
6 | 3.56 | 20.50 | 104.00 | 290.00 | |
mean | 3.56 | 20.02 | 100.02 | 291.83 | |
180 | 1 | 3.61 | 21.70 | 108.00 | 304.00 |
2 | 3.70 | 19.90 | 99.90 | 293.00 | |
3 | 3.78 | 21.50 | 109.00 | 295.00 | |
mean | 3.70 | 21.03 | 105.63 | 297.33 | |
320 | 1 | 3.60 | 19.50 | 98.50 | 299.00 |
2 | 3.70 | 19.30 | 99.00 | 299.00 | |
3 | 3.79 | 20.00 | 102.00 | 290.00 | |
mean | 3.70 | 19.60 | 99.83 | 296.00 | |
560 | 1 | 3.82 | 19.30 | 104.00 | 294.00 |
2 | 3.65 | 21.20 | 114.00 | 302.00 | |
3 | 3.82 | 19.70 | 104.00 | 299.00 | |
mean | 3.76 | 20.07 | 107.33 | 298.33 | |
1000 | 1 | 3.70 | 20.20 | 104.00 | 278.00 |
2 | 3.70 | 21.30 | 110.00 | 293.00 | |
3 | 3.79 | 22.60 | 115.00 | 315.00 | |
mean | 3.73 | 21.37 | 109.67 | 295.33 | |
1800 | 1 | 3.57 | 19.20 | 96.20 | 272.00 |
2 | 3.69 | 21.50 | 114.00 | 329.00 | |
3 | 3.38 | 19.30 | 104.00 | 301.00 | |
mean | 3.55 | 20.00 | 104.73 | 300.67 |
inoculum (day 0) cell density = 1.05 x 10^4 cells/mL
Mean areas under the groth curve and growth rates and respective percentages of the control
nominal concentration [mg/L] |
mean area under the growth curve | % control | mean growth rate (0-96 h) |
% control |
control | 265.8 | 100 | 1.407 | 100 |
180 | 275.4 | 104 | 1.412 | 100 |
320 | 267.5 | 101 | 1.410 | 100 |
560 | 276.7 | 104 | 1.412 | 100 |
1000 | 278.8 | 105 | 1.410 | 100 |
1800 | 274.9 | 103 | 1.414 | 101 |
Description of key information
The toxicity of the test item on the green algae Pseudokirchneriella subcapitata (former: Selenastrum capricornutum) was determined in a GLP study according to OECD 201 except the extension of test duration to 96 h. The 96-h EC50 was determined to be >1800 mg/L (nominal).
Key value for chemical safety assessment
- EC50 for freshwater algae:
- 1 800 mg/L
Additional information
The toxicity of test item on the green algae Pseudokirchneriella subcapitata (formar: Selenastrum capricornutum) was determined in a GLP study according to OECD 201 except the extension of duration time to 96 h. The algae was exposed to 0 (control), 180, 320, 560, 1000 and 1800 mg/L of the test substance in culture medium, equivalent to geometric mean measured concentrations of <18, 170, 315, 540, 930 and 1760 mg/L at the beginning. No impact on the biomass and the groth rate was observed after 96 h at 1800 mg/L. The 96 h EC50 value of >1800 mg/L (nominal) was concluded.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.