Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Sep 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
density, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Sep 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Qualifier:
according to guideline
Guideline:
other: ISO 2099 1972
Type of method:
pycnometer method
Type:
density
Density:
ca. 953.55 g/L
Temp.:
20 °C
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Sep 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
Flash point measured according to analytical test method ASTM D 92.
Type of method:
open cup
Flash point apparatus:
other: Cleveland open cup
Flash point:
ca. 294 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: There are no values given for pressure. Atmospheric conditions (P = 1013 hPa) assumed due to open cup method.
Reason / purpose for cross-reference:
reference to same study
Reference
Endpoint:
viscosity
Type of information:
experimental study
Adequacy of study:
key study
Study period:
Sep 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Certificate of Analysis
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to same study
Principles of method if other than guideline:
Kinematic viscosity at 40°C measured according to analytical test method ASTM D445.
Type of method:
capillary viscometer (static)
Temp.:
40°C
Parameter:
kinematic viscosity (in mm²/s)
Value:
30.2

Data source

Reference
Reference Type:
other: Oleon NV Certificate of Analysis
Title:
Unnamed
Year:
2017

Materials and methods

Principles of method if other than guideline:
Pour point measured according to internal analytical test method ASTM D97.
Type of method:
pour point

Test material

Constituent 1
Chemical structure
Reference substance name:
2,2-bis[[(1-oxononyl)oxy]methyl]propane-1,3-diyl dinonan-1-oate
EC Number:
238-430-8
EC Name:
2,2-bis[[(1-oxononyl)oxy]methyl]propane-1,3-diyl dinonan-1-oate
Cas Number:
14450-05-6
Molecular formula:
C41H76O8
IUPAC Name:
3-(nonanoyloxy)-2,2-bis[(nonanoyloxy)methyl]propyl nonanoate

Results and discussion

Melting / freezing point
Melting / freezing pt.:
4 °C
Atm. press.:
ca. 1 013 hPa
Remarks on result:
other: There are no values given for pressure. Pour point assumed to be measured at atmospheric conditions (P = 1013 hPa).

Applicant's summary and conclusion