Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
other: internal method based on official guideline
Principles of method if other than guideline:
The sample was dispersed, stirred and ultrasonicated prior the analytical characterisation by light scattering.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Percentile:
D10
Mean:
ca. 15.577 µm
Remarks on result:
other: Sonicated for 2 minutes
Percentile:
D50
Mean:
ca. 51.663 µm
Remarks on result:
other: Sonicated for 2 minutes
Percentile:
D90
Mean:
ca. 113.098 µm
Remarks on result:
other: Sonicated for 2 minutes
Conclusions:
The substance particle size distribution was measured by light scattering and the results are_
D10 =15.577 µm
D50 = 51.663 µm
D90 = 113.98 µm
Executive summary:

Method


Laser Scattering/Diffraction. 


Results


The substance particle size distribution was measured by light scattering and the results are:
D10 =15.577 µm
D50 = 51.663 µm
D90 = 113.98 µm

Description of key information

D10= 15.577 µm
D50= 51.663 µm
D90= 113.98 µm

Additional information

The particle size distribution was determined by light scattering and resulted to have the following parameters


D10 =15.577 µm


D50 = 51.663 µm


D90 = 113.98 µm