Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus

Test material

Constituent 1
Reference substance name:
Zanthoxylum, ext.
EC Number:
310-094-8
EC Name:
Zanthoxylum, ext.
Cas Number:
102242-62-6
Molecular formula:
NA
IUPAC Name:
Zanthoxylum ext
Test material form:
liquid: viscous

Results and discussion

Flash point
Key result
Flash point:
86 °C
Atm. press.:
101.3 kPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The measurements were carried out at 987 mbar atmospheric pressure.
Two test were performed and the same behaviour was abserved in both determinations: The Zanthoxylum ext. ignite at 86°C.