Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 January 2018 - 01 February 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Identity: RM1006114
Appearance: White creamy solid (at 20°C)
Storage conditions: Room temperature (15 to 25°C)
Batch number: RL 686/15
Purity: 100%
Expiry date: 30 October 2018
Date received: 12 November 2015
Key result
Test procedure:
burning rate test: preliminary screening test
Burning time:
ca. 10 s
Remarks on result:
other: The substance melted and burned with a yellow flame, which extinguished approximately 10 seconds after the removal of the burner flame. Combustion did not propagate along the train.
Interpretation of results:
GHS criteria not met
Conclusions:
The substance is not highly flammable.
Executive summary:

The substance melted and burned with a yellow flame, which extinguished approximately 10 seconds after the removal of the burner flame. Combustion did not propagate along the train. As a negative result was obtained in the preliminary test, a definitive burning rate test was not required. The substance is not highly flammable.

Endpoint:
pyrophoric solids
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the substance is known to be stable in contact with air at room temperature for prolonged periods of time (days) and hence, the classification procedure does not need to be applied
Endpoint:
substances / mixtures which in contact with water emit flammable gases
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
the study does not need to be conducted because the experience in production or handling shows that the substance does not react with water, e.g. the substance is manufactured with water or washed with water

Description of key information

The substance was not highly flammable. The substance is also not pyrophoric and does not give rise to flammable gases in contact with water.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The substance melted and burned with a yellow flame, which extinguished approximately 10 seconds after the removal of the burner flame. Combustion did not propagate along the train.

As a negative result was obtained in the preliminary test, a definitive burning rate test was not required.