Endpoint:
relative self-ignition temperature (solids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2008
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
other: UN Test E.1 and E.2
GLP compliance:
no
Key result
Remarks on result:
no self ignition observed under the test conditions
Conclusions:
In the tests according to UN E.1 and E.2, no autoignition was observed.

Description of key information

In the tests according to UN E.1 and E.2, no autoignition was observed.