Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 203-062-9 | CAS number: 102-86-3
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Flash point
Administrative data
- Endpoint:
- flash point of flammable liquids
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- From 22/12/2017 to 25/07/2018
- Reliability:
- 1 (reliable without restriction)
Data source
Reference
- Reference Type:
- study report
- Title:
- Unnamed
- Year:
- 2 018
- Report date:
- 2018
Materials and methods
Test guidelineopen allclose all
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.9 (Flash-Point)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- closed cup
- Flash point apparatus:
- Setaflash apparatus
Test material
- Reference substance name:
- Trihexylamine
- EC Number:
- 203-062-9
- EC Name:
- Trihexylamine
- Cas Number:
- 102-86-3
- Molecular formula:
- C18H39N
- IUPAC Name:
- trihexylamine
Constituent 1
Results and discussion
Flash point
- Key result
- Flash point:
- 132 °C
- Atm. press.:
- 101.3 kPa
Any other information on results incl. tables
The measured flash point value for the reference substance glycerol, 193.5°C is within the control cards limits and complies with the validation criteria of 195.0+/-4.0°C.
The flash point of the reference substances CRM, 74.5 °C respects also the checking cards limits and complies with the validation criteria of 73.9 +/- 2 °C
The flash point of the test item was estimated at 131.5°C during the pre-test.
The flash point of the test item was estimated at 131°C during the first determination. An automatic correction was applied to the obtained result because the ambient pressure was not 101.3 kPa but 96.0 kPa. With this correction, the flash point value is 132.5°C at 101.3 kPa.
The flash point was detected at 131°C during the second determination and the same automatic correction was applied because the ambient pressure was 96.1 kPa. With this correction, the flash point value is 132.5°C at 101.3 kPa.
Applicant's summary and conclusion
- Interpretation of results:
- GHS criteria not met
- Conclusions:
- The corrected flash point of the test item was determined to be 132°C at 101.3 kPa (lowest value of two independent determinations).
- Executive summary:
A study was performed to determine the flash point of the test item Tri-n-hexylamine. The method followed was designed to be compliant with the Method A.9 of Commission Regulation No. 440/2008, “Flash Point” and followed GLP. The flash point of the test item is determined with a closed cup tester, by an equilibrium method called “Small Scale” (commonly known as Setaflash). The substance is placed into a test cup and heated using a temperature gradient program. Ignition trials are carried out in order to ascertain whether or not the sample flashes at the temperature tested. A pre-test followed by two determinations were conducted. For the pre-test, a flash point of 131.5°C was observed. This data was used to select the range of temperatures for the following determinations.
Determinations 1 and 2 both gave a corrected flash point of 132.5°C at 101.3 kPa.
Moreover the flash point of the reference substances glycerol and CRM respects the checking cards limits.
The corrected flash point of the test item was determined to be 132°C at 101.3 kPa (lowest value of two independent determinations).
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.

EU Privacy Disclaimer