Registration Dossier

Environmental fate & pathways

Henry's Law constant

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
Henry's law constant
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Study period:
2018-06-27
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
accepted calculation method
Qualifier:
no guideline available
Principles of method if other than guideline:
calculation of Henry's Law constant based on measured vapour pressure and water solubility
GLP compliance:
no
H:
13 293.6 Pa m³/mol
Temp.:
25 °C
Conclusions:
The calculated Henry's Law constant is 13293.6 Pa m3/mol.
Executive summary:

The Henry's Law Coonstant was calculated for one exemplary structure of the UVCB (see attached figure) using the measured vapour pressure and water solubility. The calculated Henry's Law constant is 13293.6 Pa m3/mol.

Description of key information

The Henry's Law Coonstant was calculated for one exemplary structure of the UVCB (see attached figure) using the measured vapour pressure and water solubility. The calculated Henry's Law constant is 13293.6 Pa m3/mol.

Key value for chemical safety assessment

Henry's law constant (H) (in Pa m³/mol):
13 293.6
at the temperature of:
25 °C

Additional information