Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
10 March 2017 - 21 March 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Specific details on test material used for the study:
Batch/Lot Number: 150205
Appearance: Blue powder
Purity: As a UVCB purity is considered as 100%
Key result
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
substance does not ignite and propagate combustion either by burning with flame or smouldering along 200 mm of the powder train within the 2 minutes test period
Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item considered flammable if the main test take less than 45 seconds. In all other cases the test item is not considered flammable.
The test item ignited but the flame did not spread further. Therefore, the substance is considered not to be highly flammable.

Description of key information

The test item was considered not to be highly flammable in the conditions of this test.

Key value for chemical safety assessment

Additional information

Justification for classification or non-classification