Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07/03/2018-19/03/2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 102 (Melting point / Melting Range)
Version / remarks:
1995
Qualifier:
according to guideline
Guideline:
EU Method A.1 (Melting / Freezing Temperature)
GLP compliance:
yes (incl. QA statement)
Type of method:
differential scanning calorimetry
Remarks:
results confirmed by capillary method

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of tetrahydroxysilane and choline chloride and calcium chloride and water
IUPAC Name:
Reaction mass of tetrahydroxysilane and choline chloride and calcium chloride and water
Test material form:
liquid
Specific details on test material used for the study:
batch number: 17I13
appearance: light yellow, transparent clear liquid

Results and discussion

Melting / freezing point
Key result
Melting / freezing pt.:
< -80 °C
Atm. press.:
ca. 986 hPa

Applicant's summary and conclusion

Conclusions:
The test item YaraVita Actisil has no melting point down to - 80 °C at atmospheric pressure (984-989 hPa) as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1. and OECD Test Guideline 102 (1995).
Executive summary:

The objective of this study was the determination of the melting temperature of the test item according to

·           Regulation EC No. 440/2008 Method A.1. Melting/Freezing Temperature

·           OECD Test Guideline 102 (1995) Melting Point / Melting Range

The test item YaraVita Actisil has no melting point down to - 80 °C at atmospheric pressure (984-989 hPa) as determined by differential scanning calorimetry according to Regulation EC No. 440/2008 Method A.1. and OECD Test Guideline 102 (1995).