Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12th September to 28th November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Type of method:
static method
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Kyoeisha 7061302
- Expiration date of the lot/batch: No Data
- Purity test date: No Data

STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material:
- Stability under test conditions:
- Solubility and stability of the test substance in the solvent/vehicle:
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium:

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:

FORM AS APPLIED IN THE TEST (if different from that of starting material)

TYPE OF BIOCIDE/PESTICIDE FORMULATION (if applicable)

OTHER SPECIFICS:
Key result
Temp.:
20 °C
Vapour pressure:
4.4 Pa
Conclusions:
The study found that the vapour pressure was 4.4 Pa at 20°C.

Description of key information

The study found that the vapour pressure was 4.4 Pa at 20°C.

Key value for chemical safety assessment

Vapour pressure:
4.4 Pa
at the temperature of:
20 °C

Additional information