Administrative data

Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
august 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Anton Paar Model CLA 5 Automatic Cleveland Flash & Fire Point Tester

Test material

Constituent 1
Chemical structure
Reference substance name:
Reaction mass of L-isoleucine and octadecan-1-ol and ethanesulphonic acid and docosan-1-ol
EC Number:
931-105-8
Cas Number:
1156505-34-8
Molecular formula:
C26-30H56-64O5NS
IUPAC Name:
Reaction mass of L-isoleucine and octadecan-1-ol and ethanesulphonic acid and docosan-1-ol
Constituent 2
Chemical structure
Reference substance name:
Octadecan-1-ol
EC Number:
204-017-6
EC Name:
Octadecan-1-ol
Cas Number:
112-92-5
Molecular formula:
C18H38O
IUPAC Name:
octadecan-1-ol
Constituent 3
Chemical structure
Reference substance name:
Docosan-1-ol
EC Number:
211-546-6
EC Name:
Docosan-1-ol
Cas Number:
661-19-8
Molecular formula:
C22H46O
IUPAC Name:
docosan-1-ol
Constituent 4
Chemical structure
Reference substance name:
Icosan-1-ol
EC Number:
211-119-4
EC Name:
Icosan-1-ol
Cas Number:
629-96-9
Molecular formula:
C20H42O
IUPAC Name:
icosan-1-ol
Test material form:
solid: flakes

Results and discussion

Flash point
Key result
Flash point:
230 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Flash point is 230C > 200C
Executive summary:

Flash point is 230C > 200C using equivalent method to ASTM D92