Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: Bureau of Indian Standard (BIS, Indian Standard) IS No. 2401C/2012
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2015
Type of method:
closed cup
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: Lot#11/CYP/2016
- Expiration date of the lot/batch: Dec 2017

STABILITY AND STORAGE CONDITIONS OF
TEST MATERIAL
- Storage condition of test material: Stored at RT, protected from heat, light & moisture.
- Stability under test conditions: Stable
- Solubility and stability of the test substance in the solvent/vehicle: Soluble in ethanol & acetone
- Reactivity of the test substance with the solvent/vehicle of the cell culture medium: None

TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing: No
Key result
Flash point:
128 °C
Atm. press.:
110.325 kPa
Key result
Test procedure:
sustaining combustion, test conditions 60°C, 60 s
Result:
sustaining combustion
Interpretation of results:
GHS criteria not met
Conclusions:
The flash point study on test substance was performed according to IS 2401C/2012 by close cup method. The flash point of test was found to be 128 oC.
Executive summary:

The flash point of test substance as determined by close cup method was found to be 128 oC.

Description of key information

The flash point study on test substance was performed according to IS 2401C/2012 by close cup method. The flash point of test substance is 128 oC.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
128 °C

Additional information

Flash point of test subsatnce as determined by closed cup method is 128 oC.