Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Toxicological information

Genetic toxicity: in vitro

Currently viewing:

Administrative data

Endpoint:
in vitro gene mutation study in mammalian cells
Type of information:
experimental study
Adequacy of study:
key study
Study period:
July 20, 2016 to May 25, 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 490 (In Vitro Mammalian Cell Gene Mutation Tests Using the Thymidine Kinase Gene)
GLP compliance:
yes
Type of assay:
in vitro mammalian cell transformation assay

Test material

Constituent 1
Chemical structure
Reference substance name:
Reference substance 001
Cas Number:
1078712-76-1
Molecular formula:
C23-27H49-59N (Substance is a UVCB)
Test material form:
liquid

Method

Species / strain
Species / strain / cell type:
mouse lymphoma L5178Y cells
Metabolic activation:
with and without
Metabolic activation system:
S9
Test concentrations with justification for top dose:
Following solubility checks performed in-house, the test item was accurately weighed and formulated in dimethyl sulfoxide (DMSO) prior to serial dilutions being prepared. The test item was considered to be a complex mixture (UVCB) therefore the maximum proposed dose level in the solubility test was set at 5000 μg/mL, the maximum recommended dose level, and no correction for the purity of the test item was applied. However, the test item was not suitable for dosing at this concentration. The concentration was therefore reduced until a suspension suitable for dosing was achieved at 1250 μg/mL. There was no marked change in pH when the test item was dosed into media and the osmolality did not increase by more than 50 mOsm.
Vehicle / solvent:
DMSO
Controls
Untreated negative controls:
no
Negative solvent / vehicle controls:
yes
True negative controls:
no
Positive controls:
yes
Positive control substance:
cyclophosphamide
ethylmethanesulphonate

Results and discussion

Test results
Key result
Species / strain:
mouse lymphoma L5178Y cells
Metabolic activation:
with and without
Genotoxicity:
negative
Cytotoxicity / choice of top concentrations:
cytotoxicity
Vehicle controls validity:
valid
Untreated negative controls validity:
not applicable
Positive controls validity:
valid

Any other information on results incl. tables

There was evidence of only very modest toxicity following exposure to the test item in the 4 and 24-hour exposure groups in the absence of metabolic activation, as indicated by the %RSG and RTG values when compared to that of the Preliminary Toxicity Test. This difference in toxicity was considered to be due to the greasy / oily nature of the test item precipitate resulting in variable exposure of the test item to the cells. However, it should be noted that the precipitate observations were consistent with those of the Preliminary Toxicity Test. The test item was therefore considered to have been adequately tested. There was no evidence of any significant reductions in viability (%V) in

any of the three exposure groups, indicating that residual toxicity had not occurred. Acceptable levels of toxicity were seen with the positive control substances.

Precipitate of the test item was observed at 625 μg/mL in the 4-hour exposure groups in both the absence and presence of metabolic activation, and at 156.25 μg/mL in the 24-hour exposure group in the absence of metabolic activation.

The vehicle controls had mutant frequency values that were considered acceptable for the L5178Y cell line at the TK +/- locus. The positive controls produced marked increases in the mutant frequency per viable cell achieving the acceptability criterion, indicating that the test system was operating satisfactorily, and that the metabolic activation system was functional.

The test item did not induce any toxicologically significant or dose related (linear-trend) increases in the mutant frequency x 10 -^6 per viable cell at any of the dose levels (including precipitating dose levels as recommended by the OECD 490 Guideline), in any of the three exposure groups.

Applicant's summary and conclusion

Conclusions:
The test item did not induce any increases in the mutant frequency at the TK +/- locus in L5178Y cells that exceeded the GEF, consequently it is considered to be non-mutagenic in this assay.
Executive summary:

Introduction

The study was conducted according to a method that was designed to assess the potential mutagenicity of the test item on the thymidine kinase, TK +/-, locus of the L5178Y mouse lymphoma cell line. The method was designed to be compatible with the OECD Guidelines for Testing of Chemicals No 490 "In Vitro Mammalian Cell Gene Mutation Tests Using the Thymidine Kinase Gene" adopted 28 July 2015, Method B17 of Commission Regulation (EC) No. 440/2008 of 30 May 2008, the US EPA OPPTS 870.5300 Guideline, and in alignment with the Japanese EPA/MITI/MHW guidelines for testing of new chemical substances

Methods

One main Mutagenicity Test was performed. In this main test, L5178Y TK +/- 3.7.2c mouse lymphoma cells (heterozygous at the thymidine kinase locus) were treated with the test item at eight dose levels in duplicate, together with vehicle (DMSO), and positive controls using 4 hour exposure groups both in the absence and presence of metabolic activation (2% S9), and a 24 hour exposure group in the absence of metabolic activation.

Results

The maximum dose level used in the Mutagenicity Test was limited by the onset of test item precipitate. The vehicle control cultures had mutant frequency values that were acceptable for the L5178Y cell line at the TK +/- locus. The positive control substances induced marked increases in the mutant frequency, sufficient to indicate the satisfactory performance of the test and of the activity of the metabolizing system.

The test item did not induce any toxicologically significant increases in the mutant frequency at any of the dose levels in the main test, in any of the three exposure groups.