Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 281-468-5 | CAS number: 83950-14-5
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 28 June 2017 to 28 July 2017
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- GLP compliance:
- yes
- Analytical monitoring:
- not required
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION: stock solution was prepared in deionized water (10 g/L) additional dilutions were sone with deionized water
- Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected: from the mixed treatment plant of urban (about 66%) and industrial (about 34%) liquid sewage situated in San Rocco near Monza (Italy)
- Method of cultivation: under aeration
- Preparation of inoculum for exposure: no settlement, sludge was washed and used on day of collection
- Initial biomass concentration: 3 g SS/L - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Test temperature:
- 20°C ± 2°C
- pH:
- 7.31-7.42 at 6.25-100 mg/L
- Nominal and measured concentrations:
- pre-test 1, 10 and 100 mg/L
main study: 6.25, 12.5. 25, 50 and 100 mg/L - Details on test conditions:
- TEST SYSTEM
- Test vessel: glass bottles
- Aeration: contimuously
- No. of vessels per concentration (replicates): 5 (3 in pre-test)
- No. of vessels per blank control (replicates): 6 (3 in pre-test)
- No. of vessels per vehicle control (replicates): 5 (3 in pre-test)
- No. of vessels per abiotic control (replicates): 0 (3 in pre-test)
- Sludge concentration (weight of dry solids per volume): 1.5 g/L
- Nutrients provided for bacteria: synthetic sewage feed (as per OECD 209)
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: deionized water
- Particulate matter: none
OTHER TEST CONDITIONS
- Adjustment of pH: yes with NaOH
- Photoperiod: NA
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) : dissolved oxygen concentration over period of 6 minutes leading to calculation of the oxygen consumption rate - Reference substance (positive control):
- yes
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- 36.74 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- - Blank controls oxygen uptake rate: 22.28 mg oxygen per one gram of activated sludge in an hour (pretest 16.79%)
- Coefficient of variation of oxygen uptake rate in control replicates: 8.47% (pretest 0.20%) - Results with reference substance (positive control):
- EC50 3,5 Dichlorophenol 6.7 mg/L
- Reported statistics and error estimates:
- Probit analysis
- Validity criteria fulfilled:
- yes
- Conclusions:
- The EC50 for inhibition of respiration in bacteria from sewage sludge in 36.7 mg/L
- Executive summary:
In a test according to OECD 209, bacteria in sewage sludge were exposed to 6.25, 12.5, 25, 50 and 100 mg/L of the substance during 3 hours under continuous aeration. The inhibition of total respiration was measured over a period of 6 minutes. The EC50 was 36.7 mg/L.
Reference
Concentration |
% of inhibition total respiration rate |
6.25 mg/l |
1.72 |
12.5 mg/l |
11.14 |
25.0 mg/l |
38.70 |
50.0 mg/l |
59.88 |
100.0 mg/l |
86.63 |
Description of key information
In a test according to OECD 209, bacteria in sewage sludge were exposed to 6.25, 12.5, 25, 50 and 100 mg/L of the substance during 3 hours under continuous aeration. The inhibition of total respiration was measured over a period of 6 minutes. The EC50 was 36.7 mg/L.
Key value for chemical safety assessment
- EC50 for microorganisms:
- 36.7 mg/L
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.