Physical & Chemical properties

Particle size distribution (Granulometry)

Administrative data

Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
12 Dec 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
ISO 13320:2009
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Remarks:
Ministero della Salute, Rome, Italy
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Type of distribution:
volumetric distribution

Test material

Results and discussion

Particle sizeopen allclose all
Percentile:
D90
Mean:
3.194 µm
St. dev.:
0.214
Percentile:
D50
Mean:
1.587 µm
St. dev.:
0.074
Percentile:
D10
Mean:
0.741 µm
St. dev.:
0.028

Any other information on results incl. tables

Results

The particle size distribution was determined using the laser diffraction method with dry dispersion . The particle size distribution of the test item was determined in 12 measurements. The instrument detected a bimodal grain size distribution and generated a mean value and size distributions automatically. In Table below, the results of the particle size analysis on the sample labelled as

2MAOK-PW, are reported.

 

Measurement

 

L10D(v,0.1)

[µm]

 

L50D(v,0.5)

[µm]

L90D (v,0.9)

[µm]

1

0.732

1.571

3.175

2

0,724

1.572

3.153

3

0.729

1.555

3.068

4

0.714

1.528

3.017

5

0.726

1.520

2.961

6

0.719

1.511

2.947

7

0.745

1.510

3.068

8

0.757

1.746

3.713

9

0.809

1.710

3.379

10

0.710

1.634

3.444

11

0.769

1.633

3.238

12

0.767

1.605

3.143

 

 

 

 

MeanValue*

0.741

1.587

3.194

Standard Deviation of the population

0.028

0.074

0.214

*Mean value is calculated by the software of the apparatus Mastersizer 2000 from the entirety of data captured in each run and it is not a simple arithmetic mean.

Conclusion

According to test method ISO 13320:2009, the volume mean diameter of sample labelled as 2MAOK-PW is 1.811 µm and its 90%, 50% and 10% cumulative size distributions are 3.19 µm, 1.59 µm and 0.74 µm respectively.

Applicant's summary and conclusion