Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 947-985-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Toxicity to microorganisms
Administrative data
Link to relevant study record(s)
- Endpoint:
- activated sludge respiration inhibition testing
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 2017-07-27 to 2017-07-27
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 209 (Activated Sludge, Respiration Inhibition Test (Carbon and Ammonium Oxidation))
- Version / remarks:
- 2010
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: D26-3-3-1
- Expiration date of the lot/batch: December 2018
- Purity test date: April 11, 2017 (certificate of analysis release date)
- Purity: 47.4 wt%
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature in the dark
OTHER SPECIFICS:
- Physical state/Appearance: Brown viscous liquid - Analytical monitoring:
- no
- Remarks:
- As it was not a requirement of the Test Guidelines, no analysis was conducted to determine the homogeneity, concentration or stability of the test item formulation. This is an exception with regard to GLP and is reflected in the GLP compliance statement.
- Vehicle:
- no
- Details on test solutions:
- PREPARATION AND APPLICATION OF TEST SOLUTION (especially for difficult test substances)
- Method:
* Test Item Preparation: Activated sewage sludge micro-organisms were exposed to a series of nominal test concentrations of 10, 100 and 1000 mg/L. 2500 mg of test item was dissolved in water and the volume adjusted to 1 liter to give a 2500 mg/L stock solution from which dilutions were made to give 250 and 25 mg/L stock solutions. An aliquot (200 mL) of the 25 mg/L stock solution was dispersed with synthetic sewage (16 mL), activated sewage sludge (250 mL) and water, to a final volume of 500 mL, to give the required concentration of 10 mg/L. Similarly, aliquots (200 mL) of the 250 mg/L and 2500 mg/L stock solutions were used to prepare the test concentrations of 100 and 1000 mg/L. The 1000 mg/L test concentration was prepared in triplicate. The volumetric flasks containing the stock solutions were inverted several times to ensure homogeneity. The pH was then adjusted to 7.0 - 8.0.
* Reference Item Preparation: A reference item, 3,5-dichlorophenol, was included in the range-finding test at concentrations of 3.2, 10 and 32 mg/L in order to confirm the suitability of the inoculum. A stock solution of 0.5 g/L was prepared by dissolving the reference item directly in water with the aid of ultrasonication for approximately 25 minutes. The pH of this stock solution was measured to be pH 6.2 and was adjusted to pH 7.1 using 1.0 M NaOH. Aliquots (3.2, 10 and 32 mL) of the stock solution were removed and dispersed with activated sewage sludge (250 mL), synthetic sewage (16 mL) and water to a final volume of 500 mL to give the required concentrations of 3.2, 10 and 32 mg/L. The volumetric flask containing the reference item was inverted several times to ensure homogeneity of the solution.
- Controls: test medium without test item and treated in the same way as the test item solutions. - Test organisms (species):
- activated sludge of a predominantly domestic sewage
- Details on inoculum:
- - Name and location of sewage treatment plant where inoculum was collected: Severn Trent Water Plc sewage treatment plant at Loughborough, Leicestershire, UK.
- Preparation of inoculum for exposure: The activated sewage sludge sample was maintained on continuous aeration in the laboratory at a temperature of approximately 21ºC overnight prior to use in the test. On the day of collection the activated sewage sludge (6.5 liters) was fed synthetic sewage (325 mL). The pH of the sample on the day of the test was 7.5. Determination of the suspended solids level of the activated sewage sludge was carried out by filtering a sample (100 mL) of the activated sewage sludge. The filter paper was then dried in an oven at approximately 105 ºC for at least one hour and allowed to cool before weighing. This process was repeated until a constant weight was attained.
- Initial biomass concentration: 3.0 g/L - Test type:
- static
- Water media type:
- freshwater
- Limit test:
- no
- Total exposure duration:
- 3 h
- Hardness:
- Not reported
- Test temperature:
- 21”C
- pH:
- prior to adjustment: 7.8 - 12.0
after adjustment: 7.5 - 7.7 - Dissolved oxygen:
- 5.7 - 8.2 mg O2/L or 64 - 92% of Dissolved Oxygen Saturation Level of 8.9 mg O2/L
- Salinity:
- Not reported
- Conductivity:
- Not reported
- Nominal and measured concentrations:
- Loading rate for the test substance:
- Range-Finding Test: 10, 100 and 1000 mg/L - Details on test conditions:
- TEST SYSTEM
- Test vessel: conical flasks of 500 mL
- Type (delete if not applicable): closed (see below for aeration)
- Material, size, headspace, fill volume: 500 mL
- Aeration: aerated with clean, oil-free compressed air via narrow bore glass tubes
- No. of vessels per concentration (replicates): one flask each for 10 and 100 mg/L and three for 1000 mg/L
- No. of vessels per control (replicates): 4
- No. of vessels per abiotic control (replicates): none
TEST MEDIUM / WATER PARAMETERS
- Source/preparation of dilution water: deionized reverse osmosis water containing less than 1 mg/L Dissolved Organic Carbon (DOC)
OTHER TEST CONDITIONS
- Adjustment of pH: yes
- Light intensity: normal laboratory lighting
EFFECT PARAMETERS MEASURED (with observation intervals if applicable) :
* Observations were made on the test preparations throughout the test period. Observations of the test item vessels at 0 hours were made prior to addition of activated sewage sludge.
* The pH of test preparations was measured at the test start (i.e. after the addition of activated sludge) and at the end of the 3-Hour incubation period using a Hach HQ40d Flexi handheld meter.
* The oxygen concentrations in all vessels were measured after 30 minutes contact time.
* The rate of respiration for each flask was measured over the linear portion of the oxygen consumption trace (where possible between 7 mg O2/L and 2 mg O2/L). In the case of a rapid oxygen consumption, measurements may have been outside this range but the oxygen consumption was always within the linear portion of the respiration curve. In the case of low oxygen consumption, the rate was determined over an approximate 10 minute period.
TEST CONCENTRATIONS
- Range finding study : yes
- Test concentrations: 10, 100 and 1000 mg/L
- Results used to determine the conditions for the definitive study: yes - Reference substance (positive control):
- yes
- Remarks:
- 3,5-Dichlorophenol
- Key result
- Duration:
- 3 h
- Dose descriptor:
- EC50
- Effect conc.:
- > 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Key result
- Duration:
- 3 h
- Dose descriptor:
- NOEC
- Effect conc.:
- 1 000 mg/L
- Nominal / measured:
- nominal
- Conc. based on:
- test mat.
- Basis for effect:
- inhibition of total respiration
- Details on results:
- - Any observations (e.g. precipitation) that might cause a difference between measured and nominal values: no data
- Effect concentrations exceeding solubility of substance in test medium: no data
- Blank controls oxygen uptake rate: ~40 mg O2/L/hour
- Coefficient of variation of oxygen uptake rate in control replicates: not more than 30% at the end of the test.
- The effect of the test item on the respiration of activated sewage sludge gave a 3-Hour EC50 value of greater than 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L.
- It was considered unnecessary and unrealistic to test at concentrations in excess of 1000 mg/L. - Results with reference substance (positive control):
- - 3-h EC50 = 6.6 mg/L, 95% confidence limits 4.9 to 9.0 mg/L which lies within the range 2 to 25 mg/L for total respiration suggesting the suitability of the test conditions and the sludge.
- Reported statistics and error estimates:
- - The percentage inhibition values were plotted against concentration for the reference item only, a line fitted using the Xlfit software package (IDBS) and the EC10, EC20, EC50 and EC80 values determined from the equation for the fitted line.
- 95% confidence limits were calculated for the reference item EC50 value using the method of Litchfield and Wilcoxon (Litchfield and Wilcoxon, 1949).
- For the NOEC, one way analysis of variance incorporating Bartlett's test for homogeneity of variance (Sokal and Rohlf, 1981) and Dunnett's multiple comparison procedure for comparing several treatments with a control (Dunnett, 1955). - Validity criteria fulfilled:
- yes
- Conclusions:
- An activated sludge respiration inhibition test (according to OECD guideline 209) with activated sludge from a predominantly domestic sewage treatment plant resulted in a 3-h EC50 > 1000 mg/L. The No Observed Effect Concentration (NOEC) after 3 hours exposure was 1000 mg/L. The results of the test can be considered reliable without restriction.
Reference
Dissolved Oxygen Concentrations of the Test Preparations after 30 Minutes Contact Time in the Range-Finding Test
Nominal |
Dissolved Oxygen Concentration |
Expressed as a Percentage of a Dissolved Oxygen Saturation Level of 8.9 mg O2/L |
|
Control |
R1 |
6.2 |
70 |
R2 |
6.6 |
74 |
|
R3 |
7.2 |
81 |
|
R4 |
6.0 |
67 |
|
Test Item |
10 |
6.2 |
70 |
100 |
6.1 |
69 |
|
1000 R1 |
5.9 |
66 |
|
1000 R2 |
5.7 |
64 |
|
1000 R3 |
6.0 |
67 |
|
3,5-dichlorophenol |
3.2 |
6.5 |
73 |
10 |
7.2 |
81 |
|
32 |
8.2 |
92 |
R1– R4= Replicates 1 to 4
Oxygen Consumption Rates and Percentage Inhibition Values after 3 Hours Contact Time in the Range-Finding Test
Nominal |
Initial O2 |
Measurement Period |
Final O2Reading |
O2Consumption Rates |
% |
|
Control |
R1 |
5.7 |
6 |
1.7 |
40.0 |
- |
R2 |
6.0 |
6 |
2.0 |
40.0 |
- |
|
R3 |
5.9 |
6 |
1.9 |
40.0 |
- |
|
R4 |
5.8 |
5 |
2.3 |
42.0 |
- |
|
Test Item |
10 |
5.5 |
5 |
2.0 |
42.0 |
[4] |
100 |
5.7 |
6 |
1.8 |
39.0 |
4 |
|
1000 R1 |
5.9 |
6 |
1.8 |
41.0 |
[1] |
|
1000 R2 |
5.9 |
6 |
1.8 |
41.0 |
[1] |
|
1000 R3 |
6.1 |
6 |
2.0 |
41.0 |
[1] |
|
3,5-dichlorophenol |
3.2 |
6.5 |
10 |
2.0 |
27.0 |
33 |
10 |
7.3 |
10 |
4.6 |
16.2 |
60 |
|
32 |
8.3 |
10 |
7.4 |
5.4 |
87 |
R1– R4= Replicates 1 to 4
[Increase in respiration rate as compared to controls]
Description of key information
The study of Bayliss (2016), investigating the toxicity of the test item to microorganisms according to OECD guideline 209, was considered as the key study for endpoint coverage. The 3-h EC50 was > 1000 mg/L. The 3-h EC10 and the 3-h NOEC were >1000 and 1000 mg/L, respectively.
Key value for chemical safety assessment
- EC10 or NOEC for microorganisms:
- 1 000 mg/L
Additional information
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.
