Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20 August 2018 - 03 September 2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
equivalent or similar to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.4 (Vapour Pressure)
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Key result
Temp.:
ca. 25 °C
Vapour pressure:
< 0.005 Pa
Conclusions:
The vapor pressure of RM1008606 has been determined to be less than 4.6 x 10-3 Pa at 25 °C.
Executive summary:

The vapor pressure of RM1008606 has been determined to be less than 4.6 x 10-3 Pa at 25 °C, using the vapor pressure balance method, designed to be compatible with Method A.4 Vapour Pressure of Commission Regulation (EC) No 440/2008 (as amended) of 30 May 2008, and Method 104 of the OECD Guidelines for Testing of Chemicals, 23 March 2006.

Description of key information

The vapor pressure of RM1008606 has been determined to be less than 4.6 x 10-3 Pa at 25 °C, using the vapor pressure balance method, designed to be compatible with Method A.4 Vapour Pressure of Commission Regulation (EC) No 440/2008 (as amended) of 30 May 2008, and Method 104 of the OECD Guidelines for Testing of Chemicals, 23 March 2006.

Key value for chemical safety assessment

Vapour pressure:
0.005 Pa
at the temperature of:
25 °C

Additional information