Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Chemical structure
Reference substance name:
4-chloro-5-sulphamoylbenzoic acid
EC Number:
214-882-1
EC Name:
4-chloro-5-sulphamoylbenzoic acid
Cas Number:
1205-30-7
Molecular formula:
C7H6O4NClS
IUPAC Name:
4-chloro-3-sulfamoylbenzoic acid
Test material form:
solid: particulate/powder

Results and discussion

Small-scale preliminary tests
Key result
Parameter:
other: If there are no structural alerts within the structure then the explosive properties can be
Remarks on result:
not measured/tested
Remarks:
If there are no structural alerts within the structure then the explosive properties can be predicted negative.

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
Based on the chemical structure of the test item the result for the explosive properties has been predicted negative.

Categories Display