Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Referenceopen allclose all

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
supporting study
Study period:
1990
Reliability:
4 (not assignable)
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
not specified
Type of method:
other: non specified
Key result
Flash point:
ca. 127 °F
Atm. press.:
ca. 101.3 kPa
Conclusions:
Flash point is 127°F
Executive summary:

In a method A9 of Directive84/449/EEC test, Flash point is 127°F (53°C)

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Qualifier:
according to guideline
Guideline:
other: ASTM D3828
GLP compliance:
no
Other quality assurance:
other: Impact Analytical procedure SOP-THR-005
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
ca. 83 °C
Atm. press.:
ca. 1 010 mBar
Interpretation of results:
GHS criteria not met
Conclusions:
An Erdco Rapid Tester (Setaflash) small scale closed cup flash point tester was used for this flash point determination following ASTM D3828: the flash point for the test material was determined to be 83 ºC.

Description of key information

Depending of study results, flash point may be as low as 53°C≤60°C. The product may be regarded as light heating oil therefore classification Flam. Liq. 3 according to CLP table 2.6.1.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
53 °C

Additional information