Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2018-07-19 - 2018-11-14
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
Regulation (EC) No. 1907/2006, Council Regulation (EC) No. 440/2008
EC A.9. method (2008) and ISO 3679 (March 2015)
Deviations:
yes
Remarks:
The gaseous phase of the test item of the flask exceeded 15% of its total capacity; the test item was not at a temp of at least 10 °C under the assumed flash point for the first assay. These were not considered to have affected the results obtained.
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Specific details on test material used for the study:
Lot: WR180327A
Expiry date: 31 March 2019
Key result
Flash point:
> 130 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C

Reference materials

Identification

n-nonane 99%

Last validation of the test

19 July 2018

Periodicity of validation (in months)

12

Results

33.9 °C ± 0.5 °C

Theoretical value

32.0 °C

Conformity

Yes following ISO 3679 tolerance limits

Identification

acetone >99%

Last validation of the test

25 July 2018

Periodicity of validation (in months)

12

Results

-15.9 °C ± 0.5 °C

Theoretical value

-17.0 °C

Conformity

Yes following ISO 3679 tolerance limits

Interpretation of results:
GHS criteria not met
Executive summary:

The flash point determination of the test substance was done following closed cup method. No flash point was observed up to 130 °C. Therefore, the test substance was considered to be non-flammable.

Description of key information

The flash point determination of the test substance was done following closed cup method. No flash point was observed up to 130 °C. Therefore,the test substance was considered to be non-flammable.

FP > 130 °C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
130 °C

Additional information

As per the available data for flash point, based on criteria mentioned in CLP regulation the substance was considered to be non flammable.