Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Density

Currently viewing:

Administrative data

Endpoint:
relative density
Data waiving:
study technically not feasible
Justification for data waiving:
other:
Justification for type of information:
In several non-GLP pre-tests for finding a suitable method for determining the density of MATE CONCRETE no reliable method could be ascertained.
1. The substance is very sticky. Therefore, it can’t be ground with mortar grinder and pestle.Therefore the determination of the density with the pycnometer method for solids is not possible.
2. Through heating up to 80 °C the test item did not have flow ability to perform the melting procedure for the determination of the density with the pycnometer method.
3. While trying to determine the density with the Hydrostatic balance over a period of hours no stable value could be detected. This was certainly caused by entrapped air in the test item.
Therefore under these circumstances it is not possible to determine the density of MATE CONCRETE with reliable results.
All steps are in detail described in the document attached.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion