Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
08-Sept-2016
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Principles of method if other than guideline:
- Principle of test: Particle size analysis by laser diffraction
- Short description of test conditions:
- Parameters analysed / observed: particle size
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of particle tested:
other: Bulk substance
Type of distribution:
volumetric distribution
Key result
Percentile:
D10
Mean:
10.41 µm
St. dev.:
0
Key result
Percentile:
D50
Mean:
46.17 µm
St. dev.:
0
Key result
Percentile:
D90
Mean:
145.16 µm
St. dev.:
0
Conclusions:
10% of the particles are below 10.41 μm, 50% of the particles are below 46.17 μm and 90% of the particles are below 145.16 μm, width = 2.15, VMD = 63,82 µm

Description of key information

Percentile       Mean particle size (um)

D10              10.41

D50              46.17

D90              145.16