Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
24 Nov 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions - Method A: Particle Size Distribution (effective hydrodynamic radius)
Version / remarks:
1981
Qualifier:
according to guideline
Guideline:
EPA OPPTS 830.7520 (Particle Size, Fiber Length, and Diameter Distribution)
Version / remarks:
1996
Qualifier:
according to guideline
Guideline:
ISO 13320 (Particle size analysis - Laser diffraction methods)
Version / remarks:
2009
GLP compliance:
yes (incl. QA statement)
Type of method:
Laser scattering/diffraction
Type of particle tested:
primary particle
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Name of the test item (as cited by study report): Tellurium diethyldithiocarbamate
- Batch No.of test material: 60700109
- Expiration date of the batch: 2018-07-10
- Purity test date: 99.19%
- Appearance: Light orange to yellow powder


STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: Room temperature (20 +/- 5 C)
Key result
Percentile:
D50
Mean:
7.7 µm
Remarks on result:
other: Average of 2 test series
Percentile:
D10
Mean:
1.1 µm
Remarks on result:
other: Average of 2 test series
Percentile:
D90
Mean:
15.9 µm
Remarks on result:
other: Average of 2 test series

Description of key information

The test item has a median particle size of D50= 7.7 µm, which was determined by laser diffraction measurement.

Additional information