Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Remarks:
the substance is a solid with a low melting point (liquid at the tested temperature)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 December 2017 to 06 December 2017
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
non-GLP
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
248.1 °C
Atm. press.:
101.3 kPa

Ramp Rate (ºC)

Flash Point (ºC)

 

5.0

248.3

 

2.0

248.0

Flash not registered until 250.0ºC

2.0

248.0

Flash not registered until 252ºC

 

Interpretation of results:
GHS criteria not met
Conclusions:
The flash point of the substance is 248.1°C

Description of key information

The flash point of the substance is 248.1°C

Key value for chemical safety assessment

Flash point at 101 325 Pa:
248 °C

Additional information