Registration Dossier

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-11-07
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
The determination was performed with CILAS.
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Mass median aerodynamic diameter:
ca. 7 µm
Percentile:
D10
Mean:
0.47 µm
Remarks on result:
other: St. dev. is not provided in the study report
Percentile:
D50
Mean:
4.99 µm
Remarks on result:
other: St. dev. is not provided in the study report
Percentile:
other: D98
Mean:
20.59 µm
Remarks on result:
other: St. dev. is not provided in the study report

Description of key information

Particle size:

D 10: 0.47 µm

D 50: 4.99 µm

D98: 20.59 µm

Mean diameter: 7.00 µm

Additional information

particle size distribution by laser diffraction