Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
September 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Version / remarks:
in accordance with EC 440/2008
Deviations:
no
GLP compliance:
no
Remarks:
Quality assurance was applied and signed for, similar to current GLP practises
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
Herzog HFP 380 (equipped with an ASTM 10C thermometer)
Dynamic viscosity of test material:
280 mPa*s
Specific details on test material used for the study:
Ketjenflex 8
Key result
Flash point:
202 °C
Atm. press.:
102.1 kPa
Conclusions:
The flash point of Ketjenflex 8 (NETSA [N-ethyltoluene-(o/p)-sulphonamide]) is 202.0ºC at 102.1 kPa.
Executive summary:

The test item Ketjenflex 8 (NETSA [N-ethyltoluene-(o/p)-sulphonamide]) has a flash point of 202.0ºC at 102.1 kPa according to the guideline ASTM D93.

Description of key information

Ketjenflex 8 (NETSA [N-ethyltoluene-(o/p)-sulphonamide]) has a flash point of 202.0ºC at 102.1 kPa according to the guideline ASTM D93.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
202 °C

Additional information

Categories Display