Administrative data

Endpoint:
density
Remarks:
density
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28-30 March 2012
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Well conducted and well described study according to GLP and OECD guideline 109 without any deviation
Cross-referenceopen allclose all
Reason / purpose for cross-reference:
reference to same study
Reason / purpose for cross-reference:
reference to other study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
OECD Guideline 109 (Density of Liquids and Solids)
Deviations:
no
Principles of method if other than guideline:
Not applicable
GLP compliance:
yes (incl. QA statement)
Type of method:
pycnometer method

Test material

Constituent 1
Chemical structure
Reference substance name:
4,4’-Bis[sec-alkyl(C10-C13)phenyl]iodonium tetrakis(pentafluorophenyl)borate
EC Number:
810-260-4
Cas Number:
1115251-57-4
IUPAC Name:
4,4’-Bis[sec-alkyl(C10-C13)phenyl]iodonium tetrakis(pentafluorophenyl)borate
Test material form:
liquid: viscous
Details on test material:
- Physical state: Viscous, clear, amber liquid
- Lot/batch No.: 11GP0077
- Date of Receipt: 13 February 2012
- Expiration date of the lot/batch: January 2014
- Storage condition of test material: Room temperature, away from light

Results and discussion

Density
Type:
density
Density:
1.4 g/cm³
Temp.:
20 °C
Remarks on result:
other: ± 0.0004 g/cm3

Any other information on results incl. tables

Table 4.4/1: Measured values

First Determination

Error rel.

Error abs.

Temperature

20.2 °C

0.1

Density of water

0.998203 g/cm3

2.00 %

0.0002

Weighing#

m1

m2

m3

Item

Pycn. empty

Pycn + H2O

Pycn. + test item

Mass in g

30.2068

39.9998

43.9422

Temperature in °C

20.2

20.2

20.2

Volume of Pycnometer

9.8106 cm3

Density of Test Item

1.4001 g/cm3

0.0105 %

0.0001

Second Determination

Error rel.

Error abs.

Temperature

20.0 °C

0.1

Density of water

0.998203 g/cm3

2.00 %

0.0002

Weighing#

m1

m2

m3

Item

Pycn. empty

Pycn. + H2O

Pycn. + test item

Mass in g

31.1793

41.136

45.1391

Temperature in °C

20

20

20

Volume of Pycnometer

9.9746 cm3

Density of Test Item

1.3995 g/cm3

0.0103%

0.0001

Pycn.: Pycnometer

Applicant's summary and conclusion

Conclusions:
Under the test conditions, the density of test material was determined to be 1.3998 ± 0.0004 g/cm3 at 20.0 ± 0.2 °C.
Executive summary:

A GLP study was conducted to determine the density of test material by pycnometer method according to OECD Guideline 109.

Under the test conditions, the density of test material was determined to be 1.3998 ± 0.0004 g/cm3 at 20.0 ± 0.2 °C.