Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Viscosity

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The dynamic viscosity of the test item was determined to be 1450 mPa*s at 20 °C and 239 mPa*s at 40 °C.

The kinematic viscosity of the test item was determined to be 1460 mPa*s at 20 °C and 244 mPa*s at 40 °C.

Key value for chemical safety assessment

Viscosity:
1 450 mPa · s (dynamic)
at the temperature of:
20 °C

Additional information

A GLP study was conducted in accordance with the OECD Guideline for the Testing of Chemicals 114 "Viscosity of liquids" using a capillary viscosimeter for determination of the kinematic viscosity and the dynamic viscosity was calculated by multiplication of the kinematic viscosity with the density. The GLP study determined the kinematic viscosity to be 1460 mm2 /s at 20 °C and 244 mm2/s at 40 °C. The dynamic viscosity was calculated to be 1450 mP*s at 20°C and 239 mPa*s at 40°C.

This was supported by a non-GLP study which was conducted using a Ubbelohde viscosimeter for determination of the kinematic viscosity and the dynamic viscosity was calculated by multiplication of the kinematic viscosity with the density. The study determined the kinematic viscosity to be 924.4 mm2 /s at 25 °C and 251.1 mm2/s at 40 °C. The dynamic viscosity was calculated to be 916.6 mP*s at 25°C and 246.4 mPa*s at 40°C.

The results from the recent GLP study were chosen as key value for the viscosity.